MPH-02, MPB-02, MPD-02
Motor, Mechanical Axis System, Measuring Systems
5-33
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
1000
4004
0
P
0018
0
P
3
0051
0
P
4004
0
P
0018
0
P
4047)/1000
0
(P
2
3
2
0051)
0
(P
0051
0
P
Drive)
4041(Indra
0
P
∗
−
−
∗
−
−
∗
−
−
∗
−
−
∗
−
−
∗
−
−
+
−
−
+
−
−
=
−
−
P-0-0051, Torque/force constant (Diax/EcoDrive)
P-0-4047, Motor inductance (Diax/EcoDrive)
P-0-0018, Number of pole pairs/pole pair distance (Diax/EcoDrive)
P-0-4004, Magnetizing current (Diax/EcoDrive)
Fig. 5-23:
Conversion to IndraDrive parameter values (in mH)
list parameter P-0-4042 (IndraDrive)
→
enter the value "1,0" in each of the five lines!
4
4047
0
P
4039
0
P
rive)
(Diax/EcoD
e)
(IndraDriv
−
−
=
−
−
P-0-4047, Motor inductance (Diax/EcoDrive)
Fig. 5-24:
Conversion to IndraDrive parameter values (in mH)
(
)
[
]
(
)
4040
-
0
-
P
4041
-
0
-
P
0535
0
P
30
4040
-
0
-
P
4039
-
0
-
P
4040
-
0
-
P
4039
-
0
-
P
4041
-
0
-
P
0018
0
P
0531
0
P
3
10
0529
-
0
-
P
e)
(IndraDriv
+
∗
−
−
∗
∗
+
+
⋅
−
−
∗
−
−
∗
∗
∗
=
P-0-0531, Stall current factor (Diax/EcoDrive)
P-0-0018, Number of pole pairs/pole pair distance (Diax/EcoDrive)
P...4039: P-0-4039, Stator leakage inductance (IndraDrive)
P...4040: P-0-4040, Rotor leakage inductance
P...4041: P-0-4041, Motor magnetizing inductance (IndraDrive)
P-0-0535, Motor voltage at no load (Diax/EcoDrive); in %
Fig. 5-25:
Conversion to IndraDrive parameter values (in %)
4
4047
0
P
4040
0
P
rive)
(Diax/EcoD
e)
(IndraDriv
−
−
=
−
−
P-0-4047, Motor inductance (Diax/EcoDrive)
Fig. 5-26:
Conversion to IndraDrive parameter values (in mH)
(
) (
)
(
)
−
−
−
∗
−
−
+
−
−
+
−
−
∗
−
−
−
−
+
−
−
∗
−
−
+
−
−
∗
=
2
4040
0
P
4039
0
P
4040
0
P
4039
0
P
4041
0
P
4040
0
P
4041
0
P
4039
0
P
4041
0
P
0,4
0528
-
0
-
P
e)
(IndraDriv
P-0-4041, Motor magnetizing inductance; see above (IndraDrive)
P-0-4040, Rotor leakage inductance; see above (IndraDrive)
P-0-4039, Stator leakage inductance; see above (IndraDrive)
Fig. 5-27:
Calculation from IndraDrive parameter values calculated above
)
4012
0
(P
)
4004
0
(P
2
100000
4043
-
0
-
P
rive)
(Diax/EcoD
rive)
(Diax/EcoD
e)
(IndraDriv
−
−
∗
−
−
∗
∗
=
P-0-4004, Magnetizing current
P-0-4012, Slip factor
Fig. 5-28:
Conversion to IndraDrive parameter values (in ms)
The rated speed of the motor is only required for rotary asynchronous
motors in "open-loop" operation!
P-0-4041, Motor magnetizing
inductance
P-0-4042, Characteristic of motor
magnetizing inductance
P-0-4039, Stator leakage
inductance
P-0-0529, Scaling of stall current
limit
P-0-4040, Rotor leakage
inductance
P-0-0528, Flux control loop
proportional gain
P-0-4043, Rotor time constant
P-0-4036, Rated motor speed