MPH-02, MPB-02, MPD-02
Extended Drive Functions
9-39
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
The analog outputs are scaled (range of values per V) in the following
parameters:
•
P-0-0422, Analog output, assignment A, scaling [1/V]
•
P-0-0425, Analog output, assignment B, scaling [1/V]
The reference of the analog outputs is defined (value at output of 0 V) in
the following parameters:
•
P-0-0418, Analog output, assignment A, signal value at 0V
•
P-0-0419, Analog output, assignment B, signal value at 0V
Note:
The parameters for "...assignment A..." act on the analog
outputs 1 and 3.
The parameters for "...assignment B..." act on the analog
outputs 2 and 4.
Via the respective bits of
P-0-0427, Control parameter of analog output
definitions are made for the respective assignment (A or B) with regard to
•
limitation/overflow
and
•
clock time of the output value updating.
In addition, a definition is made for each of the four possible analog
outputs to determine whether it outputs voltage
•
according to assignment A or B
- or -
•
voltage signals independent of drive (transmitted by master
communication).
Outputting Predefined Standard Parameters
All status variables and signals of the drive that can be output via analog
outputs are listed in parameter
P-0-0426, Analog output IDN list of
assignable parameters
.
The assignment is made by entering the IDN of the parameter in the
respective signal selection parameter:
•
P-0-0420, Analog output, assignment A, signal selection
•
P-0-0423, Analog output, assignment B, signal selection
The output mode for the assigned parameters has to be set in
P-0-0427,
Control parameter of analog output
.
Note:
The parameters for "...assignment A..." act on the analog
outputs 1 and 3.
The parameters for "...assignment B..." act on the analog
outputs 2 and 4.
Scaling
Reference Point
Other Settings