5-88
Motor, Mechanical Axis System, Measuring Systems
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Diagnostic Messages of Scaling Setting
If inadmissible scaling settings were made, they are detected when
switching from parameter mode (communication phase 2) to operating
mode (communication phase 4). The drive in this case does not reach the
operating mode and, according to setting, displays the following
command errors:
•
C0122 Incorr. parameteriz. of motor enc. (mechanical system)
•
C0123 Modulo value for motor encoder cannot be displayed
•
C0127 Incorr. parameteriz. of opt. enc. (mechanical system)
•
C0128 Modulo value for optional encoder cannot be displayed
•
C0140 Rotary scaling not allowed
•
C0101 Invalid parameters (see S-0-0021)
•
C0102 Limit error in parameter (-> S-0-0021)
•
C0103 Parameter conversion error (->S-0-0021)
Example of Scaling Settings
There are many possibilities to make settings for the scaling type. The
table below shows useful settings for which there aren’t any command
errors to be expected:
Mechanical system
Encoder
Useful scaling type settings
Motor
Load
gear
Feed
spindle
Motor
encoder
External
encoder
Motor reference
Load reference
Modulo
available
not
available
rotary
no
rotary
rotary
possible
rotary
---
possible
available/
not avail.
available
rotary
no
---
linear
possible
available
not
available
rotary
rotary
rotary
rotary
possible
rotary
---
possible
rotary
rotary
---
linear
possible
rotary
---
possible
rotary
available/
not avail.
available
rotary
linear
---
linear
possible
linear
not
available
not
available
linear
---
---
linear
not possible
Fig. 5-101: Useful scaling type settings depending on mechanical drive system