MPH-02, MPB-02, MPD-02
Operating Modes
7-51
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Example:
Relative positioning without residual path storage with target
position
=
700 (current position
=
200); interrupting and restarting a
relative positioning block without residual path storage
v
01
01
DK000028v01_en.fh7
positioning block
acceptance:
P-0-4060 (bit 0)
t
in standstill:
S-0-0013,
Class 3
diagnostics (bit 1)
S-0-0419,
Positioning command
acknowledge
end position reached:
P-0-4061,
Positioning block
status word (bit 4)
P-0-4051,
Positioning block
acknowledgment
P-0-4026,
Positioning block
selection
velocity
profile
S-0-0124,
Standstill
window
x = 200
x = 350
pos. block 01
positioning inputs valid
positioning acknowledgment outputs show negated status
of positioning inputs
after valid block acceptance, positioning acknowledgment outputs
show non-inverted status of positioning inputs
positioning block 01
x = 1050
01
t
R
interruption
t
R
Drive HALT (AH):
S-0-0134,
Master control
word (bit 13)
Fig. 7-30:
Interrupting a relative positioning block without residual path storage
Note:
According to master communication, positioning block
acceptance takes place by toggling bit 0 in S-0-0346 or by a 0-
1 edge of bit 0 in P-0-4060.
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com