10-54
Handling, Diagnostic and Service Functions
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
4. see
P-0-1511, Circuit board code control section
(list element 3)
for serial number of control section and write it down
5. send purchase order to Bosch Rexroth indicating serial number (from
P-0-1511) and desired firmware configuration (from S-0-0030)
6. receive adjusted firmware type plate from Bosch Rexroth to stick it on
type plate of control section so that content of S-0-0030 complies with
firmware description on type plate
If there hasn’t any functional package been previously enabled by the
customer, the additional licensing can start with step 4. In step 5 the
desired new firmware configuration then cannot be read from S-0-0030,
but has to be taken from the overview of firmware types (see "Firmware
Types That Can Be Ordered" in chapter "System Overview: Functional
Packages").
Note:
For handling the purchase order please contact your
Bosch Rexroth sales representative!
The scope of supply consists of
•
ordered new firmware type as FWA file incl. parameter file
(as files or on MMC)
•
adjusted firmware type plate (to stick on)
Monitoring the Enabling of Functional Packages
As regards the enabling of functional packages, a check is run in the
transition command from phase 2 to phase 3 (cf.
S-0-0127, C0100
Communication phase 3 transition check
) to find out whether several
alternative packages have been selected simultaneously. If yes, the error
message C0101 is generated and the parameter IDN "P-0-2003" is
entered in the list parameter
S-0-0021, IDN list of invalid operating data
for communication phase 2
.
See also Troubleshooting Guide for "C0101 Invalid parameters (->
S-0-0021)"