MPH-02, MPB-02, MPD-02
Master Communication
4-59
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
8
X15 pin 33
9
X15 pin 15
10
X15 pin 34
11
X15 pin 16
12
X15 pin 17
13
X15 pin 36
14
X15 pin 18
15
X15 pin 37
Fig. 4-37:
Assignment of signal status word to digital outputs
See also "Configurable Signal Status Word" in chapter "Master
Communication"
Note:
Connector pin assignment is described in the separate
documentation "Project Planning Manual for Control Sections"
in chapter "Interfaces".
Notes on Commissioning/Parameterization
Positioning Block Mode with Parallel Interface
See also "Positioning Block Mode" in chapter "Operating Modes"
Note:
With the device configuration "parallel interface (PL)" the
signal control word and the signal status word are configured
accordingly when the command "load basic parameters" is
executed.
With a positive edge (0
→
1) at the strobe input (bit 0 of
P-0-4060,
Positioning control word
) a positioning block is selected and started.
The inputs for the positioning block selection are mapped to parameter
P-0-4026, Positioning block selection
.
The block selection in parameter P-0-4051 is acknowledged as soon as
the positioning block has been started. The "In-Pos" message is
simultaneously updated.
Selecting the jogging inputs causes an internal switching to the "drive-
controlled positioning" mode. The two jogging inputs are mapped to
parameter
S-0-0346, Positioning control word
(bit 1 and bit 2) and the
jogging direction is thereby determined.
Note:
The jogging inputs are also used, among other things, for
operational stop (positioning stop; cf. S-0-0346).
Examples of control of the jogging inputs
S-0-0346, Positioning control word:
•
bit 2, 1 = 01
→
j
•
bit 2, 1 = 10
→
jogging -
•
bit 2, 1 = 11
→
positioning stop
Positioning Block Selection,
Start Signal
Block Selection
Acknowledgement, "In-Pos"
Message