MPH-02, MPB-02, MPD-02
Drive Control
6-93
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Braking resistor diagnoses:
•
P-0-0844, Braking resistor load
•
P-0-0833, Braking resistor threshold
Braking resistor warnings:
•
E2820 Braking resistor overload prewarning
•
E2802 HW control of braking resistor
•
E2829 Not ready for power on
Braking resistor error messages:
•
F2820 Braking resistor overload
•
F2821 Error in control of braking resistor
•
F2825 Switch-on threshold braking resistor too low
•
F8838 Overcurrent external braking resistor
Power section warnings:
•
E8028 Overcurrent in power section
•
8057 Device overload, current limit active
Power section error message:
•
F8060 Overcurrent in power section
Reaction to signaled errors of other drives in the drive system:
•
E8058 Drive system not ready for operation
Supply in this case signals:
•
E2810 Drive system not ready for operation
Error message if supply has switched off in the case of error:
•
F2086 Error supply module
Braking Resistor