5-48
Motor, Mechanical Axis System, Measuring Systems
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Form "Parameters for Synchronous Motors"
Manufacturer,
Motor type:____________________________________
Customer, installation,
Axis
designation:___________________________________
Parameter no.
Parameter name
Value
determined
Value set
Unit
see ...
Motor Parameters
S-0-0141
Motor type
p. 5-36
P-0-4014
Type of construction of motor
p. 5-36
P-0-0051
Torque/force constant
_______
p. 5-37
P-0-0018
Number of pole pairs/pole pair
distance
PPZ/mm
p. 5-37
S-0-0113
Maximum motor speed
_______
p. 5-37
S-0-0111
Motor current at standstill
A
p. 5-37
S-0-0109
Motor peak current
A
p. 5-37
Current loop parameters
S-0-0106
Current loop proportional gain 1
V/A
p. 5-38
S-0-0107
Current loop integral action time 1
ms
p. 5-38
Field weakening range parameters
P-0-4005
Flux-generating current, limit value
A
p. 5-43
P-0-0533
Voltage loop proportional gain
A/V
p. 5-39
P-0-0534
Voltage loop integral action time
ms
p. 5-39
P-0-0535
Motor voltage at no load
80.0
%
p. 5-40
P-0-0536
Motor voltage max.
90.0
%
p. 5-40
Motor data
P-0-4016
Direct-axis inductance of motor
mH
p. 5-43
P-0-4017
Quadrature-axis inductance of motor
mH
p. 5-43
P-0-4002
Charact. of quadrature-axis induct. of
motor, inductances
p. 5-43
P-0-4003
Charact. of quadrature-axis inductance
of motor, currents
p. 5-43
P-0-4048
Stator resistance
ohm
p. 5-39
P-0-0510
Rotor inertia
_______
p. 5-39
Temperature monitoring parameters
P-0-0512
Temperature sensor
--
p. 5-39
S-0-0201
Motor warning temperature
°C
p. 5-39
S-0-0204
Motor shutdown temperature
°C
p. 5-39
Position encoder parameters
P-0-0074
Encoder type 1 (motor encoder)
p. 5-30
S-0-0116
Feedback 1 Resolution
Fig. 5-66: Parameter protocol for synchronous motors
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com