MPH-02, MPB-02, MPD-02
Operating Modes
7-105
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Pertinent Diagnostic Messages
•
A0112 Phase synchronization, encoder 1, virtual master axis
•
A0113 Phase synchronization, encoder 2, virtual master axis
•
A0114 Phase synchronization, encoder 1, real master axis
•
A0115 Phase synchronization, encoder 2, real master axis
•
A0116 Phase synchr. lagless, encoder 1, virtual master axis
•
A0117 Phase synchr. lagless, encoder 2, virtual master axis
•
A0118 Phase synchr. lagless, encoder 1, real master axis
•
A0119 Phase synchr. lagless, encoder 2, real master axis
•
C0244 Act. modulo value cycle greater than max. travel range
•
C3100 Recalculate actual value cycle
•
C3101 Act. modulo value cycle greater than max. travel range
•
C3102 Drive is still in drive enable
•
E2049 Positioning velocity >= S-0-0091
•
F2039 Maximum acceleration exceeded
Command Value Adjustment
Command value adjustment in the "phase synchronization" mode
consists of the following basic functions:
•
master axis evaluation and adjustment (real or virtual master axis)
•
electronic gear with fine adjust
•
command value processing specific to operating mode
•
dynamic
synchronization
See also section "Basic Functions of the Synchronization Modes"
P-0-0052
P-0-0053
dynam.
synchron-
ization
cmd value processing
specific to oper. mode
adjustment
of position
format
internal
cmd
value
DF000103v02_en.fh7
electronic
gear
with
fine adjust
real mas-
ter axis
encoder
virtual
master
axis pos.
P-0-0775
master axis
evaluation
and
processing
P-0-0052:
actual position value of measuring encoder
P-0-0053:
master axis position
P-0-0775:
resulting master axis position
Fig. 7-80:
Function blocks of command value processing and command value
adjustment in operating mode "phase synchronization with
real/virtual master axis"
Overview
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪