MPH-02, MPB-02, MPD-02
Extended Drive Functions
9-45
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
The respective bit in the source or target parameter is selected via
P-0-0301, Digital I/Os, bit numbers
.
Note:
When P-0-0300[i] = S-0-0000 the respective entry in
P-0-0301
is ignored!
A number of digital inputs/outputs can be used both as an input and as an
output. The operating principle (direction) of these combined
inputs/outputs is determined via the list parameter
P-0-0302, Digital I/Os,
direction
. The following applies:
•
entry
"0"
→
digital input (= default setting)
•
entry
"1"
→
digital output
Note:
When determining the operating principle (direction) of the
inputs/outputs the hardware requirements have to be taken
into consideration. The "bb" relay pins, for example, can only
be operated as output.
See also section "X31/X32, Digital and Analog Inputs/Outputs"
in documentation "Project Planning Manual for Control
Sections"
Source or Target Parameter
Operating Principle
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com