background image

2.1.2 Edition 04.10

DK

S

N

P

GR

 www.docuthek.com

D

GB

F

NL

I

E

TR

CZ

PL

RUS

H

© 2008 – 2010 Elster GmbH

Please read and keep in a safe place

 Please read through these instructions 

carefully  before  installing  or  operating.  Follow-
ing the installation, pass the instructions on to the 
operator. These instructions can also be found at 
www.docuthek.com.

Explanation of symbols
 • ,  1 ,  2 ,   

... = Action

 

= Instruction

Liability

We will not be held liable for damages resulting 
from non-observance of the instructions and non-
compliant use.

Safety instructions

Information that is relevant for safety is indicated in 
the instructions as follows:

 DANGER

Indicates potentially fatal situations.

 WARNING

Indicates possible danger to life and limb.

 CAUTION

Indicates possible material damage.

All interventions may only be carried out by qualified 
gas technicians. Electrical interventions may only be 
carried out by qualified electricians.

Conversion, spare parts

All technical changes are prohibited. Only use OEM 
spare parts.

Transport

On receipt of the product, check that the delivery is 
complete (see Part designations). Report any trans-
port damage immediately. 

Storage

Store the product in a dry place. Ambient tempera-
ture: see Technical data.

Operating instructions

Translation from the German

D

GB

F

NL

I

E

GB-1

Safety

Contents

Safety shut-off valve JSAV

Safety shut-off valve JSAV  . . . . . . . . . . . . . . . 1
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Checking the usage . . . . . . . . . . . . . . . . . . . . . 2

Type code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Part designations . . . . . . . . . . . . . . . . . . . . . . . . 2

Type label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Connecting the impulse line . . . . . . . . . . . . . . 

Tightness test . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Checking the function . . . . . . . . . . . . . . . . . . . 4

Checking the switching pressure p

so

 . . . . . . . . . 4

Checking the tightness of the valve disc. . . . . . . 4

Setting the switching pressure p

so

  . . . . . . . . 5

Replacing the spring . . . . . . . . . . . . . . . . . . . . 5
Resetting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Replacing the measuring unit. . . . . . . . . . . . . 6
Replacing the valve disc . . . . . . . . . . . . . . . . . 7
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . 9

Service life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Declaration of conformity . . . . . . . . . . . . . . . 10

Содержание JSAV

Страница 1: ...qualified gas technicians Electrical interventions may only be carried out by qualified electricians Conversion spare parts All technical changes are prohibited Only use OEM spare parts Transport On...

Страница 2: ...e inlet and outlet Part designations JSAV 25 4 1 2 6 7 5 3 JSAV 40 1 2 9 7 6 5 8 3 4 1 Measuring unit 2 Breather screw plug 3 Reset cap 4 Impulse line connection 5 Inlet 6 Outlet 7 Arrow of direction...

Страница 3: ...on and adjust ment 2 JSAV R seal pipe with approved sealing material JSAV F insert seal between pipe and unit 3 Remove screw caps or adhesive foil from the inlet and outlet on the JSAV Note direction...

Страница 4: ...open see Resetting p 5 Ensure that the breather screw plug is screwed in 2 Close all manual valves at the inlet and outlet and in the relief line CAUTION Please observe the following to ensure that th...

Страница 5: ...brown 0 308 906 4 120 220 1 74 3 2 crimson 0 308 906 5 190 400 2 8 5 8 orange yellow 0 308 906 6 300 550 4 35 8 orange green 0 308 906 7 Standard spring 2 Remove the breather screw plug JSAV 25 40 3 4...

Страница 6: ...th the valve disc assembled 1 O ring and 4 screws are enclosed 2 Detach the impulse line from the JSAV 4 5 3 Ensure that the O ring is fitted in the new measur ing unit see Figure 5 6 Follow the rever...

Страница 7: ...lacing all seals 2 Detach the impulse line from the JSAV 5 15 9 4 3 6 7 10 8 11 10 12 16 13 14 First insert the washer into the valve disc and then the O ring 17 15 18 19 16 14 Ensure that the O ring...

Страница 8: ...ring unit must be at the bot tom when the JSAV is closed If the JSAV is open apply pressure to the impulse line to close the valve 2 Detach the impulse line from the JSAV 7 6 4 5 3 Press the reset lev...

Страница 9: ...GGG 40 Diaphragm NBR valve seat aluminium valve stem stainless steel valve disc JSAV 25 40 steel with vulcanized NBR seal JSAV 50 100 aluminium with vulcanized NBR seal Service life The Pressure Equip...

Страница 10: ...eclare that the prod ucts JSAV 25 40 marked with product ID No CE 0085AS0202 and JSAV 50 100 marked with the product ID No CE 0085AR0246 comply with the requirements of the listed Directives and Stand...

Отзывы: