The Data Source value will change depending on the type of Data Source configured for each
event. When an Event Expression is used, a series of bits will indicated the True/False status of
terms in the Event Expression. For example, if you had an expression like:
Evt1 | Evt2 | (Evt3 & Evt4)
You could get a message that would trigger with:
1000000000000
0100000000000
0011000000000
First Bit = the first event name in the expression, and so on.
Custom Active Message (Required):
SMS Message:
Enter a custom message when an event goes active to be sent to the recipient(s). If
appended to a standard message, the length is limited to 60 characters.
Email Message:
Enter a custom message body that will be sent to the Recipient(s) when the event
goes active.