346
Data Movement Instructions
Section 3-8
Description
XFER(070) copies N words beginning with S (S to S+(N–1)) to the N words
beginning with D (D to D+(N–1)).
It is possible for the source words and destination words to overlap, so
XFER(070) can perform word-shift operations.
Flags
Precautions
Be sure that the source words (S to S+N–1) and destination words (D to
D+N–1) do not exceed the end of the data area.
Some time will be required to complete XFER(070) when a large number of
words is being transferred. In this case, the XFER(070) transfer might not be
completed if a power interruption occurs during execution of the instruction.
Example
When CIO 000000 is ON in the following example, the 10 words D00100
through D00109 are copied to D00200 through D00209.
Index Registers
---
Indirect addressing
using Index Registers
,IR0 to ,IR15
–2048 to +2047, IR0 to –2048 to +2047, IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –) IR0 to, –(– –) IR15
Area
N
S
D
D+
S+(N
−
1)
(N
−
1)
to
to
N words
&10
Name
Label
Operation
Error Flag
ER
OFF
&10
10
words
Summary of Contents for SYSMAC CS Series
Page 2: ......
Page 4: ...iv ...
Page 30: ...xxx ...
Page 186: ...146 List of Instructions by Function Code Section 2 4 ...
Page 1320: ...1280 Model Conversion Instructions Unit Ver 3 0 or Later Section 3 35 ...
Page 1390: ...1350 CJ series Instruction Execution Times and Number of Steps Section 4 2 ...
Page 1391: ...1351 Appendix A ASCII Code Table ASCII SP Four leftmost bits Four rightmost bits ...
Page 1392: ...1352 ASCII Code Table Appendix A ...
Page 1404: ...1364 Revision History ...