732
Table Data Processing Instructions
Section 3-17
Applicable Program Areas
Operands
C and C+1: Control words
C specifies the number of words in the range, bit 15 of C+1 indicates whether
the data will be treated as signed binary or unsigned binary, and bit 14 of C+1
indicates whether or not to output the PLC memory address of the word that
contains the minimum value to IR00.
Note C and C+1 must be in the same data area.
The following table shows the possible values of C.
R1: First word in range
R1 specifies the first word in the search range. The words from R1 to R1+(C–
1) are searched for the minimum value. (C is the number of words specified in
C.)
Note R1 and R1+C–1 must be in the same data area.
Operand Specifications
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
C+1
Data type
Index Register output
0000
Unsigned binary
No
4000
Unsigned binary
Yes
8000
Signed binary
No
C000
Signed binary
Yes
15
0
C
15
0
14
0
C+1
13
00
0000
0000
0000
Output selection
Data type
0: Unsigned binary data
1: Signed binary data
0: Does not output address to IR00.
1: Outputs address to IR00.
Number of words in range
R1
R1+(C–1)
15
0
---
to
Search range
Area
C
R1
D
CIO Area
CIO 0000 to
CIO 6142
CIO 0000 to CIO 6143
Work Area
W000 to W510
W000 to W511
Holding Bit Area
H000 to H510
H000 to H511
Summary of Contents for SYSMAC CS Series
Page 2: ......
Page 4: ...iv ...
Page 30: ...xxx ...
Page 186: ...146 List of Instructions by Function Code Section 2 4 ...
Page 1320: ...1280 Model Conversion Instructions Unit Ver 3 0 or Later Section 3 35 ...
Page 1390: ...1350 CJ series Instruction Execution Times and Number of Steps Section 4 2 ...
Page 1391: ...1351 Appendix A ASCII Code Table ASCII SP Four leftmost bits Four rightmost bits ...
Page 1392: ...1352 ASCII Code Table Appendix A ...
Page 1404: ...1364 Revision History ...