![background image](http://html1.mh-extra.com/html/omron/sysmac-cs-series/sysmac-cs-series_reference-manual_742030626.webp)
586
Special Math Instructions
Section 3-14
1,2,3...
1.
D00100 and D00102 are set to 0000.
2.
D00101 and D00103 are set to 4000.
3.
MOVD(083) is used to move the digits of the original source words to the
proper digits in the 2-word floating-point formats.
1
2
3
4
5
6
7
@MOV
@MOV
@MOV
@MOV
@MOVD
@MOVD
@MOVD
@MOVD
@FDIV
D00101
D00100
4 0 0 0 0 0 0 0
0000
4000
D00103
D00102
4 0 0 0 0 0 0 0
0000
4000