![background image](http://html1.mh-extra.com/html/omron/sysmac-cs-series/sysmac-cs-series_reference-manual_742030554.webp)
514
Conversion Instructions
Section 3-12
Flags
Example
When CIO 000000 is ON in the following example, LINE(063) copies bit 5
from D00100 to D00115 to the 16 bits in D00200.
3-12-13 LINE TO COLUMN: COLM(064)
Purpose
Converts the 16 bits of the source word to a column of bits in a 16-word range
of destination words (the same bit number in 16 consecutive words).
Ladder Symbol
Variations
Applicable Program Areas
Operands
D: First Destination Word
Specifies the first destination word. D and D+15 must be in the same data
area.
Name
Label
Operation
Error Flag
ER
ON if N is not within the specified range of 0000 to 000F.
OFF in all other cases.
Equals Flag
=
ON if D is 0000 after execution.
OFF in all other cases.
N: #0005
S:
D: D00200
to
to
&5
COLM(064)
S
D
N
S
: Source word
D
: First destination word
N
:
Bit number
Variations
Executed Each Cycle for ON Condition
COLM(064)
Executed Once for Upward Differentiation
@COLM(064)
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification
Not supported
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
Summary of Contents for SYSMAC CS Series
Page 2: ......
Page 4: ...iv ...
Page 30: ...xxx ...
Page 186: ...146 List of Instructions by Function Code Section 2 4 ...
Page 1320: ...1280 Model Conversion Instructions Unit Ver 3 0 or Later Section 3 35 ...
Page 1390: ...1350 CJ series Instruction Execution Times and Number of Steps Section 4 2 ...
Page 1391: ...1351 Appendix A ASCII Code Table ASCII SP Four leftmost bits Four rightmost bits ...
Page 1392: ...1352 ASCII Code Table Appendix A ...
Page 1404: ...1364 Revision History ...