background image

Please read this manual before switching the unit on.

Important safety information inside.

PCE Americas Inc.

711 Commerce Way 

Suite 8 

Jupiter

FL-33458

USA

From outside US: +1

Tel: (561) 320-9162

Fax: (561) 320-9176

[email protected]

www.pce-instruments.com/english

www.pce-instruments.com

PCE Instruments UK Ltd.

Units 12/13 

Southpoint Business Park 

Ensign way

Hampshire / Southampton

United Kingdom, SO31 4RF

From outside UK: +44

Tel: (0) 2380 98703 0

Fax: (0) 2380 98703 9

    [email protected]

      Manual

Paticle Counter

    PCE-MPC 10

Summary of Contents for MPC 10

Page 1: ...utside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hamps...

Page 2: ...ations 5 Power on or Power off 6 Measurement Mode 7 Setup mode 7 1 Date Time setup 7 2 Alarm setup 7 3 Sample Time 7 4 Unit C F setup 7 5 Memory View 7 6 Mass Particle setup 7 7 Auto Power Off setup 8...

Page 3: ...ure and relative humidity The series products is a delicate and practical hand held instrument the real scene and time can be displayed on color TFT LCD memory readings can be recorded in meter It Wou...

Page 4: ...Bottom Description 1 Particle Sensor 2 LCD Display 3 Page up and Setup button 4 Page down and ESC button 5 Power ON OFF button 6 Measure and Enter button 7 Memory View button 8 USB charge interface 9...

Page 5: ...RH 3 3 3 2 5um 10um 0 50 C 32 122 F 0 1 C F 1 C 2 F Particle Counter PCE MPC 10 Channel Mass Concentration Air Temperature Measure Air Temp Range Resolution Basic Accuracy Humidity Range Resolution Ba...

Page 6: ...unit will power off 6 Measurement Mode On the power on mode you can press the button to start measuring PM2 5 and PM10 the top left corner of the LCD display Counting the top right corner of the LCD...

Page 7: ...n not do measurement operation as shown below Press the button and the button to select the menu option needed then press button to enter into the appropriate settings page After entering into Date Ti...

Page 8: ...be select by 30s 1min 2min or 5min Press button and the button to select the temperature unit C F Press button and button to select storage catalog press button to view data in selected storage catal...

Page 9: ...tton and the button to select the mode particle concentration and mass concentration mode Press button and button to set the auto off time Disable Power off function is deactivated 3MIN Automatically...

Page 10: ...he product must be repaired by professionals It must use the required replacement parts in maintenance If the operating manual is changed please instruments prevail without notice Do not use in over d...

Page 11: ...Rev 160421...