Clock Instructions
Section 3-28
3-28-3 HOURS TO SECONDS: SEC(065)
Purpose
Converts time data in hours/minutes/seconds format to an equivalent time in
seconds only.
Ladder Symbol
Variations
Applicable Program Areas
Operands
S and S+1: Source Data
Set the hours/minutes/seconds source data in S and S+1, as shown in the fol-
lowing diagram. S and S+1 must be in the same data area.
C:
T:
R:
18:30:20
16:20:05
C
T
R
10 July, 1998
50 hours, 10 minutes, 15 seconds
8 July, 1998
SEC(065)
S
D
S
: First source word
D
: First destination word
Variations
Executed Each Cycle for ON Condition
SEC(065)
Executed Once for Upward Differentiation
@SEC(065)
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification
Not supported.
Block program areas
Step program areas
Subroutines
Interrupt tasks
OK
OK
OK
OK
15
8
0
7
S
15
S+1
0
Seconds: 00 to 59 (BCD)
Minutes: 00 to 59 (BCD)
Hours: 0000 to 9999 (BCD)
Summary of Contents for SYSMAC CS Series
Page 2: ......
Page 4: ...iv ...
Page 30: ...xxx ...
Page 186: ...146 List of Instructions by Function Code Section 2 4 ...
Page 1320: ...1280 Model Conversion Instructions Unit Ver 3 0 or Later Section 3 35 ...
Page 1390: ...1350 CJ series Instruction Execution Times and Number of Steps Section 4 2 ...
Page 1391: ...1351 Appendix A ASCII Code Table ASCII SP Four leftmost bits Four rightmost bits ...
Page 1392: ...1352 ASCII Code Table Appendix A ...
Page 1404: ...1364 Revision History ...