background image

Operating instruction

Maxi 3200

Coin box

Summary of Contents for Maxi 3200

Page 1: ...Operating instruction Maxi 3200 Coin box ...

Page 2: ...or safe and proper use read the instructions for use and further product related documents carefully and keep it for later use For errors technical errors printing errors and incompleteness we assume no liability ...

Page 3: ...xecution brought by us in traffic corresponds to the standards specified down Diese Erklärung gilt für alle Geräte die nach den beiliegenden technischen Unterlagen welche Bestandteile dieser Erklärung sind hergestellt werden This explanation applies to all devices after the enclosed technical documents which are components of this explanation are manufactured Einschlägige EG Richtlinien Relevant E...

Page 4: ...ifications 11 10 Programming 12 10 1 Explanation the Programming 12 10 1 1 Special function time meter DIP 1 12 10 1 2 Adjustment pre begin time DIP 2 12 10 1 3 Adjustment main time DIP 3 13 11 Bookkeeping statistic menu 14 11 1 Inquiry schema delete the statistics 14 11 2 Explanation of the bookkeeping statistic menu 14 12 Not programmable special equipments 15 12 1 Contactor 2 x 20 A 15 12 2 Con...

Page 5: ...cleaning and maintenance The device is mostly maintenance free By poor coin acceptan ce the coin runway of the mechanic single coin tester can be cleaned with a damp cloth or brush to remove any dust or de posits The metal casing can be cleaned with a damp cloth or a cleaning agent which can be dissolved in water Do not use under any circumstances thinners petrol acetone or scouring cleaning agent...

Page 6: ...Casing color Powder coated white RAL 9016 Color design foil yellow orange Design foil from customer on request Dimensions h 255 mm x w 170 mm x d 135 mm Weight ca 4 0 kg Temperature range 0 to 50 C Voltage maintenance 230 V or 24 V 50 60 Hz Switched power 6 3 A by cos phi 1 230 V 24 V Power absorption 3 3 VA Protection class I by 230 V or III by 24 V Protection type IP20 Fuse circuit board SI1 50 ...

Page 7: ... Housing lower part 2 Coin acceptor 3 Coin slot 4 Reject button for coins 5 Coin reject 6 Coin box 7 Removel of coins 8 Lock 9 Button for accounting statistics menu 10 Front plate 11 LED Display 12 Design foin standard Special equipment You can used the rejcet button for coins as door opener 1 2 3 4 5 6 7 8 9 10 11 12 ...

Page 8: ...onnection for free use 6 Connection for account statistic menu button 7 Elektrical connection 8 Fuse circuit board 9 Battery 3V CR 2032 10 DIP switch for time settings see chapter 4 11 Conntection for short time button 12 Remote start 13 Connection for time stop 14 Delete entrance 15 Connection for coin acceptor Special equipment 7 2 Illustration of electronic Circuit board MM V99 1 230 V 1 2 3 4 ...

Page 9: ...e protection ladder as function earth The floor must antistatic and conductive that not statically loads 8 2 Mounting notes The MAXI 3200 were designed for the montage on the wall and for partial into the wall The coin timer must be well fast For this please use the attachments of rear from casing The device is cabled by means of threaded metric threads on the bottom or rear The MAXI 3200 correspo...

Page 10: ...ection lead Remote start potential free Connection 230V Connection 24V MAXI 3200 MAXI 3200 230V 24V L2 PE N L3 L2 U0 U1 LH N L U0 U1 violet Earth wire green yellow blue black LN brown L1 LH violet Earth wire green yellow blue black LN brown L1 PE Remote start Remote start Lead blinding to PE clamp ...

Page 11: ... Operating the first time If the MAXI is installed can through switches on the stream The time counter is now operational and can become program Plea se test the programming through a test sprint After this test you should delete the readings to get about a correct bill The MAXI has protection a sabotage the were active if the contact of the coin acceptor is closed longer than 0 2 seconds Standard...

Page 12: ... time is indicated flashing during the pre begin time ON OFF 1 2 3 4 Minutes 1 2 4 pre begin off X ON OFF 1 2 3 4 ON OFF 1 2 3 4 ON OFF 1 2 3 4 The attitudes can you take from the following example Switch 2 ON hours are activated Switch 2 OFF minutes are activated Switch 3 ON seconds are activated Switch 3 OFF minutes are activated Switch 4 ON HQL is activated Switch 4 OFF HQL is activated If shou...

Page 13: ...h has his own value The main time is programmed in minute steps How to program the seconds To adjust a main time the DIP switches must be activated on ON With combination of the DIP switches which adjusted upwards on ON you can adjusted every main time from 1 mi nute to 255 minutes Example 10 minutes main time When the main time is running the point in the display is flashing Notice that you can g...

Page 14: ...cally the counter Operation hours counter full hours also is delete The counter counts ma ximal up to 59 and started than again with 0 If he counted over you find under Point 7 of the statistic menu the fault code 11 Impulse counter service activations 4 Counter for the quantity of full service hours The counter counts maximal up to 999 and started than again with 0 If he counted over you find und...

Page 15: ...e closing contact This special equipment can not be ordered with the special equipments cleaning button or short time impulse for washing machine door opener 12 3 Current dependent time stop The current dependent time stop offers the possibility to dis connect the main time depended on the power input of the connected device If the power input is e g under 40 80 or 100 mA as ordered then the main ...

Page 16: ...ct programming DIP switches stand wrongly correct DIP switches DIP points flashing all 5 seconds Special error Read point Special errors DIP points flashing all the time Not allowed function Redress the external malfunction Electricityinstallationsmakeleaveonlybyanelectrical specialist 12 7 Delete entrance The delete entrance offers the possibility bought time or rest time to delete with the poten...

Page 17: ...ere can not be any sabotage 7 Safety loop during impulse operation has broken Error is possible only during decrement function Check the cable 10 Impulse counter has an overflow Maximum from 999 is reached Delete impulse counter 11 Operating hours counter has an overflow Maximum from 999 is reached Delete operating hours counter 12 Service activations counter has an overflow Maximum from 999 is re...

Page 18: ...Holtkamp Electronics MAXI 3200 techn stand 09 2017 4025_09 2017 V09 2019 18 ...

Page 19: ...16 17 EU Declaration of conformity 3 Explanation of the bookkeeping statistic menu 14 Explanation the Programming 12 G General data 6 General errors 16 I Illustration of device 7 Illustration of electronic 8 Inquiry schema 14 Installation notes 9 L Legal information 5 M Maintenance 5 Malfunctions 16 Mounting instructions 9 Mounting notes 9 N Not programmable special equipments 15 O Operating the f...

Page 20: ...de Technical Stand 09 2019 We reserve the right to technical changes in the production and technical developments For technical information during our business hours Monday Thursday 8 00 a m 16 00 p m and Friday 8 00 a m 13 00 p m choose 49 541 97120 0 or visit our homepage www holtkamp de ...

Reviews: