![background image](http://html1.mh-extra.com/html/omron/sysmac-cs-series/sysmac-cs-series_reference-manual_7420301159.webp)
1119
Display Instructions: DISPLAY MESSAGE: MSG(046)
Section 3-27
3-27 Display Instructions: DISPLAY MESSAGE: MSG(046)
Purpose
Reads the specified sixteen words of extended ASCII and displays the mes-
sage on a Peripheral Device such as a Programming Console.
Ladder Symbol
Variations
D304
D305
D306
D307
060329 00200000
060330 00010000
060331 00012345
W1.0
UP
KEEP
W1.0
W1.1
STR4
A353
D300
Always ON Flag
Stores the ASCII data as a text file.
Output file: LOG.TXT
A34315
A34313
=
W0
#0023
ANDW
A352
#00FF
W0
STR4
A352
D302
Current date converted
to ASCII
MOV
#2020
D303
BCDL
D100
W100
STR8
W100
D304
MOV
#5C4C
D200
MOV
#4F47
D201
MOV
#0000
D202
TWRIT
#1
&16
D200
D300
#0D0A
D100, D101
W100, W101
Puts 2 spaces between
the date and data.
Converts the
day’s production
total to BCD.
Converts the day’s
BCD production
total to ASCII.
Directory: Root
Filename: LOG
Daily production total
&12345 dec
#000012345 BCD
#3030 hex
#3031 hex
#3233 hex
#3435 hex
MSG(046)
N
M
N
: Message number
M
: First message word
Variations
Executed Each Cycle for ON Condition
MSG(046)
Executed Once for Upward Differentiation
@MSG(046)
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification
Not supported.
Summary of Contents for SYSMAC CS Series
Page 2: ......
Page 4: ...iv ...
Page 30: ...xxx ...
Page 186: ...146 List of Instructions by Function Code Section 2 4 ...
Page 1320: ...1280 Model Conversion Instructions Unit Ver 3 0 or Later Section 3 35 ...
Page 1390: ...1350 CJ series Instruction Execution Times and Number of Steps Section 4 2 ...
Page 1391: ...1351 Appendix A ASCII Code Table ASCII SP Four leftmost bits Four rightmost bits ...
Page 1392: ...1352 ASCII Code Table Appendix A ...
Page 1404: ...1364 Revision History ...