1348
CJ-series Instruction Execution Times and Number of Steps
Section 4-2
Example:
Input variables with a 1-word data type (INT): 5
Output variables with a 1-word data type (INT): 5
Function block definition section: 100 steps
Number of steps for 1 instance = 57 + (5 + 5)
×
6 steps + 100 steps + 27 steps
= 244 steps
4-2-36 Guidelines on Converting Program Capacities from Previous
OMRON PLCs
Guidelines are provided in the following table for converting the program
capacity (unit: words) of previous OMRON PLCs (SYSMAC C200HX/HG/HE,
CVM1, or CV-series PLCs) to the program capacity (unit: steps) of the CJ-
series PLCs.
Add the following value (n) to the program capacity (unit: words) of the previ-
ous PLCs for each instruction to obtain the program capacity (unit: steps) of
the CJ-series PLCs.
For example, if OUT is used with an address of CIO 000000 to CIO 25515, the
program capacity of the previous PLC would be 2 words per instruction and
that of the CJ-series PLC would be 1 (2 – 1) step per instruction.
Contents
CS/CJ-series CPU Units
with unit version 3.0 or later
m
Call part
57 steps
n
I/O parameter
transfer part
The data type is
shown in parenthe-
ses.
1-bit I/O variable (BOOL)
6 steps
1-word I/O variable (INT,
UINT, WORD)
6 steps
2-word I/O variable (DINT,
UDINT, DWORD, REAL)
6 steps
4-word I/O variable (LINT,
ULINT, LWORD, LREAL)
12 steps
p
Number of instruc-
tion steps in func-
tion block definition
The total number of instruction steps (same as standard
user program) + 27 steps.
CJ-series steps = “a” (words) of previous PLC + n
Instructions
Variations
Value of n when
converting from
C200HX/HG/HE to
CJ Series
Value of n when
converting from
CV-series PLC or
CVM1 to CJ Series
Basic
instructions
None
OUT, SET, RSET,
or KEEP(011): –1
Other instructions:
0
0
Upward Differentiation
None
+1
Immediate Refreshing
None
0
Upward Differentiation and
Immediate Refreshing
None
+2
Special
instructions
None
0
–1
Upward Differentiation
+1
0
Immediate Refreshing
None
+3
Upward Differentiation and
Immediate Refreshing
None
+4
Summary of Contents for SYSMAC CS Series
Page 2: ......
Page 4: ...iv ...
Page 30: ...xxx ...
Page 186: ...146 List of Instructions by Function Code Section 2 4 ...
Page 1320: ...1280 Model Conversion Instructions Unit Ver 3 0 or Later Section 3 35 ...
Page 1390: ...1350 CJ series Instruction Execution Times and Number of Steps Section 4 2 ...
Page 1391: ...1351 Appendix A ASCII Code Table ASCII SP Four leftmost bits Four rightmost bits ...
Page 1392: ...1352 ASCII Code Table Appendix A ...
Page 1404: ...1364 Revision History ...