923
Step Instructions
Section 3-22
The program for this process, shown below, starts with two SNXT(009)
instructions that start processes A and B. Because of the way CIO 000001
(SW A1) and CIO 000002 (SW B1) are programmed, only one of these will be
executed with an ON execution condition to start either process A or process
B. Both of the steps for these processes end with a SNXT(009) that starts the
step (process C).
000201 SNXT(009)
024614
000000 @LD
000001
000001 AND NOT
000002
000002 SNXT(009)
010000
000003 LD NOT
000001
000004 @AND
000002
000005 SNXT(009)
010001
000006 STEP(008)
010000
000100 LD
000003
000101 SNXT(009)
010002
000102 STEP(008)
010001
000100 LD
000004
000101 SNXT(009)
010002
000102 STEP(008)
010002
000200 LD
000005
000202 STEP(008)
---
Process A
Process B
Process C
Instruction Operands
Address
Note
In the above programming, CIO 010002 is used in two
SNXT(009) instructions. This will not produce a duplication
error during the program check.
Process
C reset.
Process B
reset.
Process C
started.
Process
A reset.
Process
C started.
Process
A started.
Programming for process C
Programming for process B
Programming for process A
Summary of Contents for SYSMAC CS Series
Page 2: ......
Page 4: ...iv ...
Page 30: ...xxx ...
Page 186: ...146 List of Instructions by Function Code Section 2 4 ...
Page 1320: ...1280 Model Conversion Instructions Unit Ver 3 0 or Later Section 3 35 ...
Page 1390: ...1350 CJ series Instruction Execution Times and Number of Steps Section 4 2 ...
Page 1391: ...1351 Appendix A ASCII Code Table ASCII SP Four leftmost bits Four rightmost bits ...
Page 1392: ...1352 ASCII Code Table Appendix A ...
Page 1404: ...1364 Revision History ...