Page 1: ...QT 6600 Touch Screen Smart Terminal Reference Manual Version 1 1 December 2008 c C C ...

Page 2: ...tions to use QT 6600 system 5 Registrations This chapter explains actual registration operations with example 6 Refund mode operation This chapter explains registrations in the RF or REG mode 7 Read and reset This chapter explains detail of the read and reset operations and reports 8 Appendices These chapters show the record format and descriptions of individual files total calculation method mean...

Page 3: ...le terminal With the QT 6600 system any terminal has the same function and can be designated as the master terminal by programming 2 Software concept A flexible application system for development adopting the following methods Function classified application system 3 Terminal hardware concept Color LCD with touch panel In addition to the above the QT 6600 is also a terminal following characteristi...

Page 4: ...e the terminal and leave it power on over 12 hours After a longtime vacation initialize the terminal and restore the program data if the terminal is in malfunction and leave it power on over 12 hours QT 6600 consumes batteries for saving data during 2 minutes after turning off the terminal Do NOT power off the terminal over 10 times while a short term Except INIT or FC operation Otherwise it makes...

Page 5: ... 2 1 System keys R 29 2 2 2 Finalize keys R 30 2 2 3 Transaction keys R 30 2 3 Remote printer control R 39 2 3 1 Remote printer system configuration R 39 2 3 2 Remote printer control setting R 40 2 3 3 Remote printer output control R 41 2 3 4 Remote printer backup processes R 41 2 4 Check tracking system R 44 2 4 1 Shared check tracking system R 44 2 4 2 Shared check tracking requirement R 45 2 4 ...

Page 6: ...te terminal R 69 2 11 4 Sign on compulsory R 69 2 12 IDC Item Data Capture R 70 2 12 1 Available capturing items R 70 2 12 2 Set up the IDC start end R 73 2 12 3 How to memorize the captured items R 74 2 12 4 IDC data file structure R 75 2 12 5 IDC data type R 81 2 12 6 Transferring IDC R 82 2 13 Electronic journal R 83 2 13 1 Storing electronic journal R 83 2 13 2 Issuing electronic journal repor...

Page 7: ...ustomer busy reset R 106 3 3 16 Sound R 106 3 3 17 Print batch maintenance file R 107 3 3 18 Execute batch maintenance file R 108 3 3 19 Re index the scanning PLU file R 109 3 3 20 Licence code entry R 110 3 3 21 FTP client R 110 3 3 22 Maintenance data R 111 3 3 23 Printer logo send R 112 3 3 24 Clerk number R 113 3 3 25 Operation monitor R 113 3 4 System command execution R 114 3 4 1 X Z reporti...

Page 8: ...Split payment Dutch account R 148 4 11 Media change R 149 4 12 Eat in Takeout R 150 4 13 Scanning PLU R 150 4 14 Shift PLU R 153 4 15 Printing barcode on receipts UP 400 and UP 360 R 153 4 16 Round repeat function R 154 4 17 Mix match coupon R 155 4 18 Customer R 156 4 19 Table sharing R 157 4 20 Order character change R 157 4 21 Item search R 157 4 22 Scan Mix match R 158 4 23 Time calculation R ...

Page 9: ...Hardware configuration R 10 1 1 General configuration R 10 1 2 Hardware diagram R 11 1 3 Keyboard R 12 1 4 Display R 13 1 5 Cash drawer R 14 1 6 Input output connectors R 15 1 7 Optional peripherals R 16 1 8 System configuration R 17 ...

Page 10: ...optional devices and configurations of the QT 6600 system 1 1 General configuration C C C Touch screen panel Display on off key Pilot lamp i Button key receiver only for QT 6600 DLS Microphone Stand Customer display Power switch cover Panel fixing screw Connector cover Front view Rear view ...

Page 11: ...nter UP 400 Power supply PRT CB 8A 8B Power Power supply supply PRT CB 8A 8B Power supply Remote printer UP 360 Microphone Speaker i Button key i f CF card Power switch cover 1024 x 768 dot color LCD Max 126 key touch screen HUB Other terminals PC or LAN printer MCR QT 6046MCR AC Adptor Drawer 2 i f Drawer 1 i f Inline RS 232C COM1 RS 232C COM2 RS 232C COM3 RS 232C COM4 RS 232C COM5 RS 232C COM6 E...

Page 12: ... PLU REPORTS ESC SKIP PAGE DOWN POST ENTRY FUNC LIST FIN LIST CASH AMT TEND SEP CHK NEW OLD CHK TBL TRANS TABLE RECEIPT PAGE UP HOME END YES NO NS COVERS MENU SEAT SUBTOTAL NB REG C01 31 10 08 12 34 PM 001234 0 00 12345678901234567890 048 060 072 084 096 108 120 132 047 059 071 083 095 107 119 131 046 058 070 082 094 106 118 130 045 057 069 081 093 105 117 129 044 056 068 080 092 104 116 128 043 0...

Page 13: ... Clerk Date Time Consecutive number PLU010 PLU020 PLU030 PLU040 PLU050 PLU060 PLU070 PLU009 PLU019 PLU029 PLU039 PLU049 PLU059 PLU069 PLU008 PLU018 PLU028 PLU038 PLU048 PLU058 PLU068 PLU007 PLU017 PLU027 PLU037 PLU047 PLU057 PLU067 PLU006 PLU016 PLU026 PLU036 PLU046 PLU056 PLU066 PLU005 PLU015 PLU025 PLU035 PLU045 PLU055 PLU065 PLU004 PLU014 PLU024 PLU034 PLU044 PLU054 PLU064 PLU003 PLU013 PLU023 ...

Page 14: ...l Mount the cash register 1 Attach 2 positioning screws bottom side of the terminal 2 Mount the terminal on the top of the drawer ensuring that the feet on the bottom of the terminal go into the holes on the drawer DISPLAY SCANNER PC MODEM COM3 COM6 COM2 COM5 COM1 COM4 LAN 1 4 4 Main display brightness control 1 4 3 Menu level display part contents SHIFT PLU 1 Menu shift 1 2nd Shift PLU level 1 8 ...

Page 15: ...tors Inline connector COM port and drawer cable are located in the bottom side connector cover DISPLAY SCANNER PC MODEM COM3 COM6 COM2 COM5 COM1 COM4 SPK PS 2 KEYBOARD MIC LAN Brightness COM3 COM6 COM2 COM5 COM1 COM4 Inline 10 100Base T PS 2 Keyboard AC Adaptor Drawer 2 Drawer 1 Ext microphone Ext speaker Bottom side of the terminal Power switch ...

Page 16: ...and slip printer connect slip to COM 4 5 port If you connect the slip printer to COM 4 the automatic detection during INIT does not performed You muse program the I O parameter manually 4 Remote display RS 232C COM 3 port QT 6060D 5 Remote printer UP 400 360 RS 232C COM 4 6 port The remote printer is used for reports kitchen orders receipts 6 Inline Inline port You can use CAT5 UTP cable 7 Drawer ...

Page 17: ... shared check tracking system and floating clerk interrupt system This terminal also has check index and detail files and update them at the same timing of master When the check master goes down the backup master plays the role of check master 3 Check self master Check self master has its check tracking system files and clerk interrupt files for itself 4 Satellite The terminal which is not assigne...

Page 18: ...e system recommendation above Otherwise the system performance may be slow down Peripherals ECR definition Remote Slip PC printer printer MODEM Check master Check backup master Self master Satellite Check Check Self Terminal ECR definition master backup master w remote master printer Check master Check backup master Self master Terminal w remote printer ...

Page 19: ...1 8 2 Inline collection consolidation system Inline collection consolidation and auto programming for up to 32 terminals 1 8 3 Online collection consolidation system Online collection consolidation and auto programming for up to 32 terminals PC on line Public Private Telephone line Maximum 32 terminals C C C C C C C C C C ...

Page 20: ...mum 32 terminals ADSL FTTH MODEM ADSL FTTH MODEM VPN router VPN router Internet C C C C C C C C C C 1 8 4 Online collection consolidation system use FTP feature Online collection consolidation and auto programming for up to 32 terminals ...

Page 21: ... 2 4 2 Shared check tracking requirement R 45 2 4 3 Data backup when the master goes down R 45 2 5 Other check tracking system control R 46 2 5 1 The timing to clear check detail and index file after finalization R 46 2 5 2 Table transfer R 46 2 5 3 Store and recall R 46 2 6 Clerk control function R 48 2 6 1 Clerk interrupt R 48 2 6 2 Clerk detail memory R 49 2 6 3 Clerk training R 49 2 6 4 Manage...

Page 22: ...e captured items R 74 2 12 4 IDC data file structure R 75 2 12 5 IDC data type R 81 2 12 6 Transferring IDC R 82 2 13 Electronic journal R 83 2 13 1 Storing electronic journal R 83 2 13 2 Issuing electronic journal report R 83 2 13 3 Displaying normal electronic journal and producing guest receipts after sales R 83 2 13 4 Transferring electronic journal memory R 84 2 14 Simple time and attendance ...

Page 23: ...2 files have 200 order file numbers These files can be reset individually and separately from the terminal files This provides access to weekly and monthly total data The periodic total 1 files and 2 files have the same functions and can accumulate data with different periods The same numberofrecordsasthecorrespondingterminalfilemustbereservedforeachperiodic total files Consolidation files Consoli...

Page 24: ...age of totalizers Registered data is accumulated to totalizers which are reserved for each functions The QT 6600 has the following types of totalizers 1 Fixed totalizers Registration data is accumulated for individual terminals 2 Function key totalizers Data input by finalize or transaction keys is accumulated in totalizers for each key Operation types as well as data used in operation differ depe...

Page 25: ...ndividual function keys are found in the chapter 2 2 2 1 4 Keyboard layout Normally the keyboard is assigned functions which are required for registration of transactions The keyboard is also used for character input when entering descriptors or names during programming The QT 6600 automatically switches the keyboard to its character input function when it determines that character input is requir...

Page 26: ...termine the status of the terminal or the required subsequent action 2 1 6 1 Operation prompt Refertothepage231ofthismanualfordetails Thesemessagescannotbeadded modified or deleted 2 1 6 2 Error messages Refer to the page 228 231 of this manual for details Error messages are displayed to indicatethatanerrorhasoccurredandacompulsoryoperationmustbeperformed Allerror messages cannot be added modified...

Page 27: ...he above listed keys Also some of these keys can be programmed as validation compulsory this means that registration is not permitted until the validation of the former registration has been performed Item validation is performed directly following an item registration listed below Departments Subdepartments PLUs scanning PLUs You can program the multiple validation printing status for above items...

Page 28: ...lly released If the paper is not released for some reasons press SLIP FEED RELEASE or SLIP BACK FEED RELEASE to release the paper Before using slip printer you should program the maximum lines of slip The following two sections are other features to control slip printing format 2 1 7 4 Endorsement message print control The QT 6600 allows printing of endorsement messages on the slip printer SP 1300...

Page 29: ...osition key This key is used for returning cursor to the home position 4 End key This key is used for moving cursor to the bottom position 5 Left right up down arrow keys These keys are used for moving the cursor 6 Yes key This key is used for consenting the selection and proceeding steps 7 No key This key is used for cancelling the selection and proceeding steps 8 Mode key This key is used for ch...

Page 30: ... Normally a receipt is issued Programmability Refer to page 95 of the programming manual 2 2 3 Transaction keys Each of the transaction keys have programmable functions which may be used as required The general description of each transaction key with individual options is outlined on the following sections 1 Price inquiry key Function code 008 This key is used to confirm the price and descriptors...

Page 31: ...ability Refer to page 99 of the programming manual 13 Pick up key Function code 022 When sales receipts are removed from the drawer or when the amount in drawer exceeds the limit value sentinel function the manager performs a pick up operation This key is used for this function This operation affects media totals rather than sales totals Pick ups are made for all types of money which can be specif...

Page 32: ...is deducted from the department subdepartment PLU or gross totalizers and the net totalizers Programmability Refer to page 113 of the programming manual 23 Validation key Function code 037 Thiskeyvalidatesitemortransactionamountsonslips Validationcanbemadecompulsory for certain function keys Multiple validation can be prohibited for certain function keys 24 Receipt key Function code 038 Thiskeyiss...

Page 33: ... In case of the registration mentioned above the Price key is pressed after entering the unit price to override a unit price preset to the department subdepartment or PLU If the preset price is to be registered as it is simply press the Price key 36 Department key Function code 051 This key is used to register items for a department Programmability Refer to page 91 of the programming manual 37 Sli...

Page 34: ...rogramming manual 47 Shift PLU key Function code 065 This key is used to shift a Flat PLU key to the n th n 1 8 level Programmability Refer to page 112 of the programming manual 48 Open key Function code 067 This key is used to release the maximum amount limit or low digit limit programmable for an amount which exceeds the limit Programmability Refer to page 107 of the programming manual 49 Open 2...

Page 35: ...ctions as the multiplication key In addition this key also hasasplitpricingfunction Thefunctionisusedtocalculatethepriceperunitforparticular items which are sold in bulk in order to obtain the total amount for the number of units purchased Programmability Refer to page 109 of the programming manual 63 Square key Function code 084 This key provides the same functions as the multiplication key In ad...

Page 36: ...nother check 73 Room number key Function code 100 This key is used to recall the customer s information from the hotel server by room number 74 Room message key Function code 101 This key is used to display print the message for the designated customer 75 OBR Optical Barcode Reader key Function code 103 This key is used to enter scanning PLU code manually 76 Price change key Function code 104 This...

Page 37: ...mmability Refer to page 111 of the programming manual 89 Takeout key Function code 129 This key is used to specify if the customer takes out items Before closing a transaction press this key for the tax exemption Programmability Refer to page 111 of the programming manual 90 Store key Function code 130 This key is used for storing the check number of the registered items Allocate this key to the t...

Page 38: ...tes all preceding data registered for departments PLUs and set menus within a transaction This key must be pressed before the transaction involving the data to be invalidated is finalized It is also effective even after calculation of subtotal amount Programmability Refer to page 109 of the programming manual 106 Worktime key Function code 237 This key is used to clock in out in simple time and at...

Page 39: ...tion The printing processing of the remote printer is performed as shown in the figure below 1 A transaction is made at a terminal 2 The terminal sends printing data to the terminal with remote printer 3 The terminal with remote printer sends data to the remote printer QT 6600 QT 6600 QT 6600 Print buffer 1 Remote Printer 2 3 RS 232C printer LAN printer 1 A transaction is made at a terminal 2 The ...

Page 40: ...the printer SW No Function Reset by DTR reserved Protocol Transmision speed Parity Busy status Low power comsumption 3mm feed after auto cut ON OFF Yes No fixed DTR DSR XON XOFF See transmission speed setting See paritysetting BF full offline BF full Yes No Invalid Valid SW No 7 OFF ON OFF ON UP 400 Bottom view 1 2 3 4 5 6 7 8 9 10 1 SW No Function Data reception error Bit length Reception buffer ...

Page 41: ...ote printer error or terminal with remote printer error In case of the backup printer is assigned when the terminal which sends printing data to remote printer detects the remote printer or the terminal with remote printer abnormality the remote printer cross backup see the next section is made In case of no backup printer is assigned or the backup printer is also downed the data will be able to d...

Page 42: ...le bon double bon Check No 123456 MC 01 REG C01 15 12 2003 12 34 001234 Soft Drinks Single Bon 1 Lemon Tea Cut Check No 123456 MC 01 REG C01 15 12 2003 12 34 001234 Soft Drinks Double Bon 2 Coffee STUB Double Bon message Check No 123456 MC 01 Check number Machine ID REG C01 15 12 2003 12 34 001234 Mode Clerk Date Time Consecutive No Soft Drinks Order character 2 Coffee 3 Order printing Normal rece...

Page 43: ...1 REG C01 15 12 2003 12 34 001267 2 Steak Set Set menu 2 Medium Detail item 2 Salad 1 Pizza Main item 1 Soft Preparation 1 Cheese Condiment 1 Tomato 1 Pizza Main item 123456 Main item PLU No 1 Soft Preparation with quantity PLU No 000001 1 Cheese Condiment with quantity PLU No 000002 1 Tomato 000003 ...

Page 44: ...or multiple terminals connected to inline This means that any terminal can be used to recall a temporary closed check of one s cluster for additional registration or finalization System configuration 1 cluster system System configuration multi cluster system Order Order Up to 12 QT 6600 terminals cluster Up to 12 QT 6600 terminals cluster CHK M CHK BM CHK M CHK BM PRN 1 PRN 2 Order Order PRN 1 PRN...

Page 45: ...ordinarily registered items or functions per one table If the number of items or functions exceeds this value during registration the next block is used automatically for the following transactions Number of item blocks Ordinarily theregistrationrequiresoneitemblocks butinapartyforexample more items are registered per one table So it is necessary to define how many item blocks can be used The maxi...

Page 46: ...atus of the transferring check 1 If the transfer check is not used The entered check number is written 2 The check number is already used Add the contents to the existing contents This option is set on the page 98 of the programming manual 2 5 3 Store and recall These functions are used for the driving through purchase The check number used in store operation is defined by check No range programmi...

Page 47: ...eport is printed out the check No range will be reset After this operation the next check No by using Store function will be the range start Thisfunctionworkswiththeoption ClearingCHK TBLNo byusingthesamenumber again to Check number only Refer to page 46 of the programming manual R J Entrance Exit Temporary receipt Order receipt Receipt KITCHEN Store Recall Hamburger French Fries Hot Coffee CHK No...

Page 48: ...low the clerk interrupt function which makes it possible for multiple clerk to simultaneously use the same register If a clerk starts registration of a transaction another can be interrupt the original registration and begin a new one The original clerk can later resume the interrupted original registration You can use the clerk interrupt function with the check tracking function Notes 1 Error cor...

Page 49: ... 2 Programming options etc are controlled exactly the same way as a working clerk 3 Receipts are different from those normally used The training receipts are filled with training filler default 2 6 4 Manager mode control There is no actual REG 2 mode on the terminal but you can control some functions you want under manager control Preparation for this function 1 Set NO to any functions you want to...

Page 50: ...hen the manager returns his her office Note Another manager s intervention 1 Manager signs on 2 Open clerk window 3 Designate appropriate clerk 4 Perform manager operation 5 Manager signs off REG C01 10 10 01 12 34 000001 1 PLU0001 10 00 1 PLU0002 20 00 PLU0003 30 00 2 30 00 REG C01 10 10 01 12 34 000001 1 PLU0001 10 00 1 PLU0002 20 00 1 PLU0003 30 00 REG2 Mode 0 00 3 60 00 REG C01 10 10 01 12 34 ...

Page 51: ...the arrangement file Multiple arrangement keys can be preset on the keyboard and each key can be linked to an arrangement program The linked arrangement program is then called and executed by pressing the arrangement key The following table shows the command parameters of the arrangement key function that can be interpreted and executed by the QT 6600 Command parameters can only be separated by sp...

Page 52: ...r Used for ordinary function keys The numbers can be specified for zero suppression Note The arrangement key itself cannot be programmed for in an arrangement program 3 Mode setting Any mode key can be specified for an arrangement key function function code mode definition Used for mode keys Note 121 01 REG mode 121 02 REF mode 121 03 REG mode 122 01 X Z mode 122 02 MGR mode 122 03 Collection Cons...

Page 53: ...lue in the buffer is larger than the specified number the command execution flow jumps and continues from thepointpresetbythelabel Iftheconditionisnotmatch with the above mentioned condition the step advances to the next command I number label This is a conditional jump command If the value in the number entry buffer is less than the specified number the command execution flow jumps to the point p...

Page 54: ...enu shift number to n n 0 15 and Status stay down menu shift assignment to m m 0 2 of all clerk CLSn Set the default shift PLU level number to n n 0 8 211 nnnn Press the ESC key nnnn record No 212 nnnn Press the YES key nnnn record No 213 nnnn Press the NO key nnnn record No GET Read from key buffer incl decimal point PUT Write to key buffer incl decimal point CLL0n Set the default clerk pop up wi...

Page 55: ...tered number to the parameter save area 202 0031 Press Clear button 1111100000000 Input the operation code for system command PUT Pick up the entered number from the parameter save area KNO2 Specify the 2 key for entering the operation code 211 0045 Specify the ESC key to execute this operation ERR1 When the input number is not 1 to 9 the following commands are processed E End the program mandator...

Page 56: ...00 TERMINAL GRAPHIC LOGO AREA COMMERCIAL MESSAGE LINE 1 COMMERCIAL MESSAGE LINE 2 COMMERCIAL MESSAGE LINE 3 COMMERCIAL MESSAGE LINE 4 2 8 2 Making graphic logo procedure Before following this procedure please allocate Graphic logo file file 047 on the terminal 1 Making a bit map image file 432 104 or 432 208 pixels 1 bit color for UP 400 UP 360 2 Convert this bit map file to the internal file by e...

Page 57: ...ne moreover specify the cycle time that indicates an unit of the appropriate intervals Hourly item link file This file is used to record the Hourly item which links with the appropriate time zone You can also specify the particular totalizer for each time zone Hourly item This file is used to store the contents of the quantity and amount of each registered item The following seven files enable to ...

Page 58: ...d works in conjunction with the schedule If the scheduler is not being utilized then the grace period inputs indicated below become inactive Grace period before start time this input indicates how many minutes an employee may clock in before the scheduled clock in time Grace period after start time this input indicates how many minutes an employee may clock in after the scheduled clock in time Gra...

Page 59: ...ns of the file Employees job assign This function is used to assign a job to each employee Before assigning the job be sure to program the details of the jobs Every employee file can link to some job code files maximum 4 jobs so some employees may link to the same job code file But be sure to make individual job files if the employees work under different hourly wages Job 1 Job 2 Job 3 Job 4 Job 5...

Page 60: ...rst week First week First week Second week Second week Second week Monday Monday Monday Tuesday Sunday Monday Monday Monday Sunday Monday Monday Monday Tuesday Sunday Monday Monday Monday Shift 1 Shift 2 Shift 3 Shift 1 Shift 3 Shift 1 Shift 2 Shift 3 Shift 3 Shift 1 Shift 2 Shift 3 Shift 1 Shift 3 Shift 1 Shift 2 Shift 3 Employee 1 Employee 2 Employee 3 Employee 4 Employee 1 Employee 1 Employee 1...

Page 61: ...ily wages Overtime cost 1 Overtime cost 2 Total of daily wages Pay rate job Weekly overtime pay ratio Weekly overtime 1 Pay rate job Pay rate job Weekly 2nd overtime ratio Weekly overtime 2 cf Weeky overtime 1 Programmed weekly work time Programmed weekly overtime Weekly overtime 2 Programmed weekly overtime Flow of Time Attendance operation The following flow shows the order of Time Attendance fu...

Page 62: ...s Inthiscase clock inbymanager 2 10 2 1 Clock in operation 1 Program Not using the window and impossible to specify job code Allow to specify job code NO Display job code window NO Refer to the page 62 of the programming manual Operation 1 XXXXXX CLOCK IN When this message appears press the YES key to register the start of working hours XXXXXX REG 10 10 01 11 59 AM 001234 GLENN DEAL 11 59 AM Clock...

Page 63: ...its XXXXXX YY 2 10 2 3 Clock in operation 3 Program Display job code window YES Allow to clock in with non preset job code NO Refer to the page 62 of the programming manual Operation 1 XXXXXX CLOCK IN 2 ChoosetheappropriateJobCodefromtheCLOCK INmenu and press the YES key to register the start of working hours Job codes that are programmed in Employee file are displayed XXXXXX REG 10 10 01 11 59 AM...

Page 64: ...rking hours All job codes that are programmed in job code file are displayed XXXXXX Receipt sample MC 01 Header REG C01 12 31 2005 11 59 AM 001234 Harrison Employee character 16 digits CLOCK IN 11 59 AM Special character REC 29 time JOB Dish Washier Special character REC 33 job character If you want to change these special characters refer to the page 134 of the programming manual REG 10 10 01 11 ...

Page 65: ...s impossible to close the accounts Receipt sample MC 01 Header REG C01 12 31 2005 11 59 AM 001234 Harrison Employee character 16 digits CLOCK IN 11 59 AM Special character REC 29 time JOB Dish Washier Special character REC 33 job character CLOCK OUT 01 59 PM Special character REC 30 time WORK TIME 02 45 Special character REC 34 working hours BREAK TIME 00 45 Special character REC 35 recess CASH TI...

Page 66: ... appears press the YES key to register the end of a recess The receipt is not printed out except electronic journal 2 10 3 5 Manager operation When the manager operate CLOCK IN after signing on the manager can operate and modify any employee s record despite of corresponding employee number Following operations are possible to operate by the manager Specify the job code CLOCK IN CLOCK OUT BREAK IN...

Page 67: ...R 67 QT 6600 Reference Manual ...

Page 68: ...the terminals Be sure there is a clerk who is specified as Manager in the clerk file If no manager it may be locked to operate 2 11 1 Sign on 1 When an employee normally operate CLOCK IN OUT BREAK IN OUT the employee s attendance information is sent from the main terminal to the satellite terminals Flow of sign on Sign on OK CLOCK IN CLOCK IN unfinished Unable to Sign on E175 Error message appears...

Page 69: ...n this case only manager can sign on When the satellite terminal could receive the CLOCK IN OUT information from the master terminal only once but failed to receive after then the CLOCK IN OUT informationineachsatelliteterminalhasleftinthelastreceivedcondition Insuchcase thelastreceivedinformationcontrolemployees signon off Managercanalwayssign on 2 11 4 Sign on compulsory When the satellite termi...

Page 70: ...1 Available capturing items Select the appropriate items that should be captured and program these items into the IDC link file The available items and their contents are indicated below Items Contents File No PLU Subdepartment Department Function Pulldown group Mix match Clerk 004 003 005 002 026 051 007 The header of the transaction The report of all the detailed statements The header of the tra...

Page 71: ...074 O Subtotal 7 075 O Receipt On Off 076 Taxable amount subtotal 077 Operator number 078 Merchandise subtotal 7 080 O Food stamp subtotal 081 Multiplication 1 082 O Quantity For 1 083 O Square 1 084 O Selective item subtotal 2 085 O Tare 087 Scale 088 Cube 1 090 O New check 091 Old check 092 New Old check 093 Add check 8 094 Separate check 8 095 Two zero 00 096 Three zero 000 097 Decimal point 09...

Page 72: ...5 This function itself is not captured But the functions that are executed by this function are captured 6 This function is not captured But item itself might be an IDC target 7 When the option printed when the key is pressed is selected it is captured 8 Transferred items by the add check and the separate check are not captured 9 ST transfer is not captured 10 This function is captured only in the...

Page 73: ...you can restart IDC by performing FC or INIT 2 Refer to the page 11 of the programming manual Operation Note 1 If you stop the IDC when the IDC file is full of items you can stop the error sound without clearing any registered data 2 The necessary files for IDC File 036 Registration buffer File 063 IDC buffer File 057 059 IDC file File 804 IDC link file Item Data Capture Item Data Capture YES 0 00...

Page 74: ...PLU 0001 Header PLU 0002 Header PLU 0003 Header Total PLU 0001 PLU 0002 PLU 0003 Total IDC Buffer IDC file 1 Header PLU 0002 Header PLU 0003 IDC file 2 2 Program Store data Item only refer to the page 64 of the programming manual When an appropriate item is selected this item and the header will be captured see the illustration below Example PLU 0001 Memorized into IDC file 1 PLU 0002 Memorized in...

Page 75: ...REG 02 REF 03 REG D3 D2 00 Normal 01 Training D1 Clerk D6 Clerk newly created this check D5 D4 Clerk last opened this check D3 D2 Clerk opening this check D1 Payment D2 00 Non payment 01 Payment D1 Item Item PLU Subdepartment Department Function Cash Charge Check Credit Rec 1 CE key Rec 0 3 11 9 16 21 26 31 40 32 Type 2 Tendering amount in local currency 1 03 60 Tendering amount in foreign currenc...

Page 76: ...r 03 Mc ID Not used Deccriptor ST Original check Rec 1 Type 2 New check 0 5 9 14 60 1 3 File 1 20 26 42 2 1 4 Refer to the last page of this section File 1 Gross quantity 0 5 9 14 19 60 Type 2 1 03 Gross amount 35 Descriptor Mc ID Not Used Rec 1 3 2 New balance Rec 1 0 3 9 14 19 24 2930 Type 2 Tendering amount 1 03 60 Food stamp change amount only for FS TD Mc ID Food stamp subtotal amount Cash ch...

Page 77: ...l Selective item status Not Used Rate 0 03 Mc ID Selective item ST amount Rec 1 Type 2 Not Used Descriptor Rate decimal position 2 5 11 18 23 28 1 60 9 FIile 1 Discount amount 33 34 50 3 Selective item status 01 Selective item 1 02 Selective item 2 1 4 Refer to the last page of this section Tip 03 Mc ID Not used Amount Descriptor Rec 1 Type 2 0 5 9 14 30 60 1 3 File 1 2 0 5 9 14 60 1 3 03 Mc ID No...

Page 78: ... 19 24 26 42 1 60 9 File 1 2 Tax exempt Taxable amount 4 Taxble amount 1 Taxable amount 2 Taxable amount 3 Taxable amount 5 Taxable amount 6 TAxable amount 7 VAT exempt amount 0 03 Mc ID Rec 1 Type 2 Not Used 3 5 11 16 21 26 31 1 60 36 9 File 1 41 2 Tax status 3 46 51 Field name Taxable Taxable Taxable Taxable Taxable Taxable Taxable Tax system amount 1 amount 2 amount 3 amount 4 amount 5 amount 6...

Page 79: ...r to the last page of this section File 1 Unit price Item status 4 Amount Quantity Not used 0 3 5 15 19 17 24 Type 2 Mc ID 1 03 60 29 Rec 1 OBR code 9 2 Tax status 3 34 Shift price level 35 Descriptor 51 File 1 Target rec Target file not used Amount No Descriptor 0 3 5 11 13 18 23 Type 2 Mc ID 1 03 60 25 Rec 1 9 2 Tax status 3 30 not used 46 File 1 MM rec MM type MM discount Amount No Descriptor 0...

Page 80: ...his manual 3 Tax status Single tax VAT b1 T S1 b2 T S2 b3 T S3 b4 T S4 b5 T S5 b6 T S6 b7 T S7 b8 T S8 b9 T S9 b10 T S10 U S or Singapore b1 T S1 b2 T S2 b3 T S3 b4 F S Canada b1 T S1 b2 T S2 b3 T S3 b4 T S4 b9 Donuts tax b10 always 1 4 Item status b6 not used b5 2nd registration b4 house Bon registration b3 COUPON2 registration b2 REFUND registration b1 VOID registration ...

Page 81: ...eration DTLTYPE_CANCEL 55 Cancel DTLTYPE_TBLTR 56 Table transfer DTLTYPE_NBFEE 57 NB fee DTLTYPE_STORE 58 Store DTLTYPE_ST_PLUS 64 ST DTLTYPE_ST_MINUS 65 ST DTLTYPE_ST_CPN 66 ST CPN DTLTYPE_ST_P_PLUS 67 ST DTLTYPE_ST_P_MINUS 68 ST DTLTYPE_SIST_PERCENT_PLUS 69 SIST DTLTYPE_SIST_PERCENT_MINUS 6A SIST DTLTYPE_ST 6F ST DTLTYPE_MDST 70 MDST DTLTYPE_PRT_CHAR 71 PRINT CHAR DTLTYPE_SHARP 73 Print DTLTYPE_...

Page 82: ...master are all reset Data transferring flow IDC data in each terminal totalizer is appended to the consolidation file individually Notes Just after IDC starts the consolidation file in the collection master is cleared to receive new data Just after the receiving is over the data is remained in the consolidation file To clear this data send the Z command or the file clear command to the collection ...

Page 83: ...s if the journal memory becomes full When the memory becomes full the terminal alerts end error which you can select to alert or not to alert by programming Refer to the page 42 of the programming manual The intelligent electronic journal starts automatically and it returns to the top of the memory if the journal memory becomes full Notes Even if the electronic journal memory is full registrations...

Page 84: ... collection master has finished the job 3 PC sends the data send command to the collection master for the collected electronic journal data 4 PC receives the collection data from the master 5 Repeat step 1 4 for all satellites Data transferring flow Electronic journal data in each terminal is collected file individually Satellite 1 file Satellite 2 file Copy Copy Copy Consolidation file in Collect...

Page 85: ...w shows the order of simple time attendance function by pressing the specified keys It is possible to specify one WORKTIME key as both clock in and clock out function or specify two keys separately Refer to 4 3 7 33 Worksheet for clock in clock out in the programming manual for details CLOCK IN CLOCK OUT 2 14 1 Clock in operation This function is used to register the Starting work time Operation 1...

Page 86: ...sign 12 31 2005 11 59 Clock in time 2 14 3 Worktime display This function shows the employee s worktime Operation 1 XXXXXX C D WORKTIME XXXXXX Employee s number C D Check digit for employee number 2 14 4 Report Clock in clock out time and clock out reason are printed on the simple time and attendance report Refer to the Read Reset chapter REG 10 10 01 11 59 AM 001234 PERSONALNO REG 10 10 01 11 59 ...

Page 87: ...git in the mag stripe is treated as manager s secret number Use Track 2 If track 2 cannot read use track 1 5 Loyalty card This function is used to register the key strings such as customer discount etc by swiping magnetic card and scanning OBR code After swiping a card track 2 scanning a code the designated function in the transaction key file is executed Procedure Using swiping SWIPE key Card swi...

Page 88: ...inary data may include Pin Verification Key Indicator PVKI one character Pin Verification Value PVV 4 characters Card Verification Value or Card Verification Code CVV or CVK 3 characters End sentinel one character generally Longitudinal redundancy check LRC one character Track 2 Start sentinel one character generally Track number 1 2 3 Primary Account Number PAN up to 19 characters Usually but not...

Page 89: ...ustomer busy reset R 106 3 3 16 Sound R 106 3 3 17 Print batch maintenance file R 107 3 3 18 Execute batch maintenance file R 108 3 3 19 Re index the scanning PLU file R 109 3 3 20 Licence code entry R 110 3 3 21 FTP client R 110 3 3 22 Maintenance data R 111 3 3 23 Printer logo send R 112 3 3 24 Clerk number R 113 3 3 25 Operation monitor R 113 3 4 System command execution R 114 3 4 1 X Z reporti...

Page 90: ...is as follows Start End Hardware reset All RAM reset Inline ID definition File creation 1 File creation 2 Initialization result to E journal Revise terminal connection table Input Init code see above Initialization operation Input date time ID etc Receiving program from other terminal or CF card Start Hardware reset Initialize work area buffers flags Initialization result to E journal End Menu sel...

Page 91: ...t descriptor in English 1 default descriptor in German 4 default descriptor in French 5 default descriptor in Spanish 6 using Arabic character table 8 Always 0 COM3 Use remote printer 2 0 Use remote display 3 Always 0 Always 0 D6 D5 D4 D3 D2 D1 Set off 0 Set on 1 Significant number Significant number 3 2 IPL Initial Program Loading IPL should be made before initializing when the application softwa...

Page 92: ...urce LAN port defined as FTP server IPL target IPL Data PC C C 3 2 2 System configuration before IPL operation Insert the IPL CF card to the terminal or connect PC and target terminal Start END Restore all data IPL from CF card Store IPL data to CF card Backup all data to CF card Clear IPL data in the CF card Insert CF card more than128MB vacant ...

Page 93: ...y reset 5 Stock maintenance 6 Drawer for clerk 7 CHK Clerk interrupt 8 Order ID change 9 Error log print 10 System re configuration 11 Item Data Capture 12 EURO Change over 13 Clerk window 14 Customer 15 Customer Busy Reset 16 Recording 17 Print batch maintenance file 18 Execute batch maintenance 19 Re index scanning PLU file 20 Licence code entry 21 FTP client 22 Maintenance data 23 Printer logo ...

Page 94: ...n manager mode 3 Select 1 System Connection Check and press the YES key 4 After checking the system connection press the ESC key to return the previous menu Note If there is unrecognized terminal there it shows as below example 04 System Connection Check INLINE 10 100Mbps 01 MC 01 RS 232C Printer 1 2 4 02 MC 02 RS 232C Printer 1 03 MC 03 RS 232C Printer 01 LAN Printer 192168000060 02 192168000061 ...

Page 95: ...erk if necessary 2 Press MODE and Manager to assign manager mode 3 Select 3 Remote Off and press the YES key 4 Select all terminals or individual terminal select YES to execute this command MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 Remote On 3 Remote Off 4 Busy Reset 5 Stock Maintenance 6 Drawer for Clerk 7 CHK CLK Interrupt 8 Order ID Change 0 00 MGR C01 10 10 01 12 3...

Page 96: ...essary 2 Press MODE and Manager to assign manager mode 3 Select 4 Busy Reset and press the YES key 4 Enter the appropriate check number and then select YES to execute this command MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 Remote On 3 Remote Off 4 Busy Reset 5 Stock Maintenance 6 Drawer for Clerk 7 CHK CLK Interrupt 8 Order ID Change 0 00 Busy Reset Check No 12 OK YES 0...

Page 97: ... next PLU appears on the screen 7 Press the ESC key to terminate this sequence 8 Press the ESC key to issue receipt MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 Remote On 3 Remote Off 4 Busy Reset 5 Stock Maintenance 6 Drawer for Clerk 7 CHK CLK Interrupt 8 Order ID Change 0 00 No Descriptor Stock 1 PLU0001 0 000 0 000 0 00 No Descriptor Stock 1 PLU0001 100 000 100 000 2 ...

Page 98: ...ger to assign manager mode 3 Select 7 CHK CLK Interrupt and press the YES key The display shows Clerk name Check No list 4 Select the check No field of the appropriate clerk enter the check number within 6 digits and press the YES key 5 Press the ESC key to return the previous menu MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 Remote On 3 Remote Off 4 Busy Reset 5 Stock Ma...

Page 99: ...ecute this command Note D4 D3 D2 D1 In case of RS 232C printer D4 D3 Terminal ID number which connects with the printer D2 D1 01 Printer 1 02 Printer 2 03 Printer 3 In case of LAN printer D4 D3 Terminal ID number which sends data to the printer D2 D1 11 26 Printer 1 16 MGR C01 10 10 01 12 34 000000 Manager Mode 1 System Connection Check 2 Remote On 3 Remote Off 4 Busy Reset 5 Stock Maintenance 6 D...

Page 100: ...to print error log If you do not want to print error log press the ESC key MGR C01 10 10 01 12 34 000000 Manager Mode 3 Remote off 4 Busy Reset 5 Stock Maintenance 6 Drawer for Clerk 7 CHK CLK Interrupt 8 Order ID Change 9 Error Log Print 10 System Re configuration 0 00 ID Date Time OPE ERR JOB 01 MC 01 0603 1535 1 51 38 03 MC 03 0603 1535 22 235 22 0 00 Error Log Print Do you want to printout YES...

Page 101: ...nd at the terminal on which the Cut off icon is lit 1 Sign on a clerk if necessary 2 Press MODE and Manager to assign manager mode 3 Select 10 System Re configuration and press the YES key 4 Choose the option YES Perform system re configuration NO Abort this procedure and press the YES key Perform SystemRecofiguration operationattheterminalthat shows system error icon System Re configuration Syste...

Page 102: ...to assign manager mode 3 Select 11 Item Data Capture and press the YES key 4 Choosetheoption YES captureitemdata NO notcapture item data and press the ESC key Item Data Capture Item Data Capture YES 0 00 MGR C01 10 10 01 12 34 000000 Manager Mode 9 Error Log Print 10 System Re configuration 11 Item Data Capture 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 0 0...

Page 103: ...ey 4 If you want to proceed this step press the YES key To abort this step press the NO or ESC key 5 If you want to proceed this step enter 8888888888 and press the YES key It takes a few minutes To abort this step press the NO or ESC key Perform the same operation of all the terminals of the system MGR C01 10 10 01 12 34 000000 Manager Mode 9 Error Log Print 10 System Re configuration 11 Item Dat...

Page 104: ...ppropriate key in the clerk window 7 Press the YES key to set this program MGR C01 10 10 01 12 34 000000 Manager Mode 9 Error Log Print 10 System Re configuration 11 Item Data Capture 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 0 00 Clerk Window Clerk Window Disable 0 00 Clerk Window 1 Use this MENU Sign on OK YES 0 00 Clerk Window Clerk Window 1 Disable 2 C...

Page 105: ...ard is per formed Customer name up to 24 characters Customer title select from sub menu Customer address 1 up to 24 characters Customer address 2 up to 24 characters Customer address 3 up to 24 characters Customer address 4 up to 24 characters Customer phone No up to 12 digits Customer group select from sub menu 5 Press the ESC to set and continue to program other customer MGR C01 10 10 01 12 34 0...

Page 106: ...11 Item Data Capture 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 0 00 Busy Reset CUST No 123456 Dr Big Scientist BALANCE 45 90 DISCOUNT 3 23 RECEIPT 3 3 16 Sound This command is used to play the programmed sound file or to record to the sound file 1 Sign on a clerk if necessary 2 Press MODE and Manager to assign manager mode 3 Select 16 Recording and press t...

Page 107: ...r 15 Customer Busy Reset 16 Recording 17 Print Batch Mainte 0 00 RECEIPT MGR C01 10 10 01 12 34 000000 Manager Mode 10 System Re configuration 11 Item Data Capture 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 17 Print Batch Mainte 0 00 Print Batch Maint File Print Batch Maint File Delete Change Change 4917770088 Scan PLU0001 12 34 Group Link Dept Link DEPT01 ...

Page 108: ...er Mode 11 Item Data Capture 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 17 Print Batch Mainte 18 Execute Batch Maint 0 00 RECEIPT MGR C01 10 10 01 12 34 000000 Manager Mode 11 Item Data Capture 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 17 Print Batch Mainte 18 Execute Batch Maint 0 00 Z report for Scan item done Exe...

Page 109: ... 6 Display Re index Scan File and return the root screen automatically MGR C01 10 10 01 12 34 000000 Manager Mode 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 17 Print Batch Mainte 18 EXECUTE BATCH MAINT 19 Re Index Scan file 0 00 MGR C01 10 10 01 12 34 000000 Manager Mode 12 EURO Change over 13 Clerk Window 14 Customer 15 Customer Busy Reset 16 Recording 17 ...

Page 110: ... file 20 Licence Code Entry 0 00 Licence Code Entry Licence Code Entry OK YES 0 00 3 3 21 FTP client You can execute FTP client processing by the operation below 1 Sign on a clerk if necessary 2 Press MODE and Manager to assign manager mode 3 Select 21 FTP Client and press the YES key 4 Select the appropriate FTP server in the list and press YES MGR C01 10 10 01 12 34 000000 Manager Mode 14 Custom...

Page 111: ...er Busy Reset 16 Recording 17 Print Batch Mainte 18 EXECUTE BATCH MAINT 19 Re Index Scan file 20 Licence Code Entry 21 FTP Client 22 Maintenance Data 0 00 Maintenance Data Maintenance Data 1 Data Backup to CF 2 Maintenance Data Clear 0 00 5 Select the appropriate FTP file in the list and press YES The process programmed in the file 912 913 is executed 6 Check the execution result and press ESC to ...

Page 112: ...e edited printer logo to the external RS 232C LAN printer s 1 Sign on a clerk if necessary 2 Press MODE and Manager to assign manager mode 3 Select 23 Printer Logo Send and press the YES key 4 Select appropriate printer RS 232C printer LAN printer and press the YES key MGR C01 10 10 01 12 34 000000 Manager Mode 16 Recording 17 Print Batch Mainte 18 EXECUTE BATCH MAINT 19 Re Index Scan file 20 Lice...

Page 113: ... 3 3 25 Operation monitor You can monitor a clerk s operation by monitoring display 1 Sign on a clerk if necessary 2 Press Manager to assign manager mode 3 Enter 99990000nn nn terminal ID No to monitor and press the ST to start operation monitor Note Do not designate the monitored or monitoring terminal The display shows the screen of the monitored terminal 4 Press ESC twice break the monitoring R...

Page 114: ... D6 0 Always 0 Scanning PLU or Not found PLU report 1 Scanning PLU or Not found PLU sales by group department subdepartment report 2 Scanning PLU or Not found PLU stock by group department subdepartment report D5 3 Scanning PLU or Not found PLU out of stock by group department subdepartment report 4 Scanning PLU or Not found PLU best 50 amount by group department subdepartment report 5 Scanning PL...

Page 115: ...ssuing daily consolidation area 4 Issuing periodic 1 consolidation area 5 Issuing periodic 2 consolidation area 71 Flash 00 09 Batch report 1 10 11 Fixed totalizer 12 Transaction 14 PLU 64 PLU stock 13 Subdepartment 15 Department 16 Group 17 Clerk 19 Time zone 20 Monthly 23 Simple Time attendance D2 D1 25 Open check 28 Table analysis 58 Electronic Journal 91 Electronic journal search by date and c...

Page 116: ...14 D10 11111 Consolidation 11112 Collection and Consolidation D9 D8 00 Fixed 0 No edition 1 Editing by group D7 2 Editing by department 3 Editing by subdepartment 4 Editing by order character 0 No extraction D6 1 Inactive Zero sales 0 No extraction D5 1 By Range D4 0 Execution in X mode 1 Execution in Z mode 0 Issuing daily area D3 1 Issuing periodic 1 area 2 Issuing periodic 2 area 00 09 Batch re...

Page 117: ... COM1 Standard For MODEM or PC RS 232C COM2 Standard For Hand held scanner or Slip printer RS 232C COM3 Standard For Remote customer display RS 232C COM4 Standard For Remote printer or Slip printer RS 232C COM5 Standard For Remote printer RS 232C COM6 Standard For Remote printer DISPLAY SCANNER PC MODEM COM3 COM6 COM2 COM5 COM1 COM4 SPK PS 2 KEYBOARD MIC LAN Brightness COM6 COM3 COM2 COM5 COM1 COM...

Page 118: ...r Maximum cable length between terminal and terminal via hubs is 500m Using 100Base TX Cable length 100m hub to terminal hub to hub Maximum 2 hubs in one cluster Maximum cable length between terminal and terminal via hubs is 300m Max 100m Max 500m Max 100m Max 100m Max 100m Max 100m Max 100m Max 100m Max 100m cross cable Max 100m Max 300m Max 100m Max 100m Configuration with Hub 10BASE T 100BASE T...

Page 119: ...600 19200 38400 57600 115200 bps Error control CRC 128 or CRC 1024 Text length 128 or 1024 bytes 2 The cable diagram between the terminal and MODEM 3 The cable diagram between the terminal and PC Terminal COM 1 MODEM Pin Signal Signal Pin No name name No 3 SD TDX SD 2 2 RD RXD RD 3 7 RS RTS RS 4 8 CS CTS CS 5 1 CD DCD CD 8 4 ER DTR ER 20 6 DR DSR DR 6 9 CI RI CI 22 5 GND GND 7 DSUB25 Terminal COM ...

Page 120: ...rminal 2 X Z data consolidation for each terminal 3 X Z data collection consolidation for each terminal 4 Program data copy and upload between terminals auto program function Functions1 2 and3 canonlybeperformedfromaterminalthatisprogrammedasmaster in which consolidation files are allocated or PC 3 5 3 2 Online functions The QT 6600 can be controlled from the personal computer by connecting it to ...

Page 121: ...es accumulate registered data Periodic total 1 files These files accumulate registered data at the point of sale and can be reset independently from the daily total files Therefore the total data within specific period can be accessed by using these files Periodic total 2 files These files have same functions as the periodic total 1 files but can reset independently for getting the different perio...

Page 122: ...04 404 504 604 Department 005 105 205 305 405 505 605 Group 006 106 206 306 406 506 606 Clerk detail 011 111 211 311 411 511 611 Hourly sales 009 109 209 309 409 509 609 Monthly sales 010 110 210 310 410 510 610 Void table 012 112 212 312 412 512 612 Table analysis 018 118 218 318 418 518 618 Grand total 020 120 220 320 420 520 620 Hourly item 021 121 221 321 421 521 621 Hourly labor 014 114 214 3...

Page 123: ...he satellite in the process of registering 3 6 1 2 Z collection processing Z collection processing is performed as the figure shown below 1 When a Z collection command is started up from the master terminal the master first locks one objected terminal Z lock 2 The objected terminal sends its report data to the consolidation work file of the master terminal 3 Report data from the satellite terminal...

Page 124: ...If money declaration compulsory is set enter in drawer amount and press or NS before issuing report X Z C01 10 10 01 12 34 000000 Inline X Z 1 Collection 2 Consolidation 3 Collection Consolidation C 01 0 00 Collection Collection 1 Daily X 2 Periodic 1 X 3 Periodic 2 X 4 Daily Z 5 Periodic 1 Z 6 Periodic 2 Z C 01 0 00 Collection Daily X 1 Batch 2 Cashier Clerk 3 Customer Account 4 Others C01 0 00 C...

Page 125: ...ation is performed But during the Z consolidation satellites are locked from registrations 3 6 2 1 X consolidation processing X consolidation processing is performed as the figure shown below 1 An X consolidation command is started up from the master terminal 2 Data of the objected terminal file are sent to the master terminal and are copied to the consolidation work file 3 The data in the consoli...

Page 126: ...ll objected terminals the files of all objected terminals are cleared and then satellite s Z lock statuses are released 3 6 2 3 Z consolidation processing scanning PLU Z consolidation processing is performed as the figure shown below Satellite Master Terminal files Terminal files 1 5 2 3 4 1 A Z consolidation command is started up from the master terminal The master first locks an objected termina...

Page 127: ...ess NOTE If money declaration compulsory is set enter in drawer amount and press or NS before issuing report X Z C01 10 10 01 12 34 000000 Inline X Z 1 Collection 2 Consolidation 3 Collection Consolidation C 01 0 00 Consolidation Consolidation 1 Daily X 2 Periodic 1 X 3 Periodic 2 X 4 Daily Z 5 Periodic 1 Z 6 Periodic 2 Z C 01 0 00 Consolidation Daily X 1 Batch 2 Cashier Clerk 3 Customer Account 4...

Page 128: ...lites are locked from registrations After consolidating data from all objected terminals the master prints the details on the printer 3 6 2 1 X collection consolidation processing X collection consolidation processing is performed as the figure shown below 1 An X collection consolidation command is started up from the master terminal 2 Data of the objected terminal file are sent to the master term...

Page 129: ...olidation work file are reported on the master s printer 4 The data in the consolidation work file is added to the consolidation file 5 After the master terminal s processing completes the same processes described in item 1 to 4 are executed for all other terminals 6 The data accumulated in the consolidation file are reported on the master s printer 7 Aftertheabovecollectionprocessingcompletesfora...

Page 130: ...declaration compulsory is set enter in drawer amount and press or NS before issuing report X Z C01 10 10 01 12 34 000000 Inline X Z 1 Collection 2 Consolidation 3 Collection Consolidation C 01 0 00 Collection Consolidation Collection Consolidation 1 Daily X 2 Periodic 1 X 3 Periodic 2 X 4 Daily Z 5 Periodic 1 Z 6 Periodic 2 Z C 01 0 00 Collection Consolidation Daily X 1 Batch 2 Cashier Clerk 3 Cus...

Page 131: ...l data Caution Do not remove a CF card during sending receiving data from to it 3 7 1 Auto programming functions The QT 6600 terminal is capable of saving and loading terminal program files The terminal program file has the following transfer functions 1 Copy all terminal files send receive send activation by source terminal receive activation by target terminal This function copies all terminal f...

Page 132: ...ldown Group Set Menu Table Clerk key ID Batch X Z Clerk Detail Receipt SLIP Msg Endorse Message ARG GP1 ARG GP2 ARG GP3 ARG GP4 ARG GP5 Text Recall Check Print Graphic Logo PLU 2nd Shift PLU Scheduler Order Char Link Keyboard Character Keyboard System Connection I O Parameter Printer Connection Hourly Item Link Mix match Time Zone Employee Job Code Schedule IDC Link Euro Sub Currency Prese Auto Pg...

Page 133: ...Group Set Menu Table Clerk key ID Batch X Z Clerk Detail Receipt SLIP Msg Endorse Message ARG GP1 ARG GP2 ARG GP3 ARG GP4 ARG GP5 Text Recall Check Print Graphic Logo PLU 2nd Shift PLU Scheduler Order Char Link Keyboard Character Keyboard System Connection I O Parameter Printer Connection Hourly Item Link Mix match Time Zone Employee Job Code Schedule IDC Link Euro Sub Currency Preset Auto Pgm con...

Page 134: ... CF card 3 Insert the CF card to the slot securely Select 2 Data Restore and press the YES key 4 Select the appropriate file you want to restore X Z C01 10 10 01 12 34 000000 CF Card 1 Data Backup 2 Data Restore 3 Backup File List 4 CF Card Format 0 00 X Z C01 10 10 01 12 34 000000 Data Restore 1 FILE004P 004 2 FILE090P 090 3 FILE028P 028 0 00 ...

Page 135: ...ry 2 Press the MODE and CF CARD key to assign CF card 3 Insert the CF card to the slot securely Select 4 CF Card Format and press the YES key 4 Press the YES key to continue formatting NO means abortion Backup File List FILE001P 001 10 10 01 10 00 FILE002P 002 10 10 01 10 01 FILE003P 003 10 10 01 10 02 0 00 X Z C01 10 10 01 12 34 000000 This procedure deletes all data in the CF Card Are you sure t...

Page 136: ...R 136 Manager Operation ...

Page 137: ...ion and pulldown group function R 143 4 7 Post entry R 146 4 8 Separate check R 147 4 9 Open check R 148 4 10 Split payment Dutch account R 148 4 11 Media change R 149 4 12 Eat in Takeout R 150 4 13 Scanning PLU R 150 4 14 Shift PLU R 153 4 15 Printing barcode on receipts UP 400 and UP 360 R 153 4 16 Round repeat function R 154 4 17 Mix match coupon R 155 4 18 Customer R 156 4 19 Table sharing R 1...

Page 138: ...rk key on the keyboard or in the clerk pop up window It is the same procedure that even clerks are assigned as clerk cashier or manager 1 Clerk sign on operation Clerk key has the clerk number setting 1 Just press the appropriate CLERK key in the keyboard or in the clerk pop up window 2 Clerk sign on operation Clerk key has no clerk number setting In case of the store has many clerks to control yo...

Page 139: ...ing departments subdepartments PLUs scan PLUs partial tenders or the PRICE LOAN or PICKUP key You can only use the VOID key to cancel a registration if you have not yet started registration of the next item 1 Wrong registration is made 2 Press the VOID key to cancel the data and reregister the transaction REG 10 10 01 12 34 000001 CLK Please sign on REG C01 10 10 01 12 34 000001 0 00 Please sign o...

Page 140: ...tered during the transaction Press the CANCEL key to cancel all data registered except partial tendering during thetransaction Thisoperationletsyouclearregistereddataandrestartfromthebeginning The cancel operation must be performed before the transaction is finalized 1 Wrong registration is made REG C01 10 10 01 12 34 000001 1 PLU0001 1 00 1 PLU0002 2 00 3 PLU0003 9 00 1 PLU0004 4 00 PLU0004 4 00 ...

Page 141: ... YES key to cancel the transaction REG C01 10 10 01 12 34 000001 1 PLU0001 1 00 1 PLU0002 2 00 3 PLU0003 9 00 1 Cancel OK PLU0004 4 00 6 16 00 REG C01 10 10 01 12 34 000001 1 PLU0001 1 00 1 PLU0002 2 00 3 PLU0003 9 00 1 PLU0004 4 00 CANCEL CANCEL 0 00 Please sign on ...

Page 142: ...ual Normal registration by using the LIST and LIST key List pop up window 1 Press the LIST key or enter the list No and press the LIST key ThentheListpop upwindowisopenedonthe keyboard 2 Select the appropriate item Direct selection by using the LIST key 1 Press the appropriate record number and press the LIST key brings direct selection of the item REG C01 10 10 01 12 34 000001 1 PLU0001 10 00 PLU...

Page 143: ...the programming manual 2 Programming PLU Set menu table linking page 88 of the programming manual 3 Programming item prices page 140 of the programming manual 1 Registering a PLU linked to a set menu 4 6 2 Using the Pulldown group function PLU Parent registration Child PLU 1 Child PLU 2 Child PLU 3 Select one of these REG C01 10 10 01 12 34 000001 1 PLU0001 10 00 PLU0001 10 00 1 10 00 REG C01 10 1...

Page 144: ...6 4 Using the substitution key Normally you can select item s in a pulldown group If the customer requires to take an item from another set menu pulldown group the SUBSTITUTION key should be used 1 A PLU linked to a pulldown group is registered but no items in the list can be selected REG C01 10 10 01 12 34 000001 1 PLU0001 10 00 PLU0002 PLU0003 PLU0004 PLU0001 10 00 1 10 00 REG C01 10 10 01 12 34...

Page 145: ...ion Note Program Fast food in the Set Menu Condiment program page 45 of the programming manual 1 An multiplication of a PLU is made 2 Enter appropriate quantity and press the X key REG C01 10 10 01 12 34 000001 1 PLU0020 10 00 1 PLU0021 20 00 1 PLU0050 50 00 PLU0050 50 00 3 80 00 REG C01 10 10 01 12 34 000001 3 PLU0001 30 00 PLU0001 30 00 3 30 00 REG C01 10 10 01 12 34 000001 3 PLU0001 30 00 X 2 3...

Page 146: ...tem 1 Openthecheckanddesignate POSTENTRY by Pressing the POST ENTRY key recalls the pulldown menu screen to select items REG C01 10 10 01 12 34 000001 3 PLU0001 30 00 2 PLU0010 2 00 PLU0010 2 00 5 32 00 REG C01 10 10 01 12 34 000001 1 Lunch menu 12 00 Soup Chicken with pepper Sirloin Rare French Pea 0 00 1 12 00 REG C01 10 10 01 12 34 000001 1 Lunch menu 12 00 Soup Chicken with pepper Sirloin Rare...

Page 147: ...sferred to the other check column If you want to separate item line press KEYPAD key and enter the quantity you want to separate 4 After selecting items press the OK key in the separate check window to terminate The selected items are trans ferred to other check REG C01 10 10 01 12 34 000001 CHECK No 222222 NEW OLD 222222 REG C01 10 10 01 12 34 000001 CHECK No 222222 1 PLU0002 2 00 1 PLU0004 4 00 ...

Page 148: ...ared total receipts per customer Receipt for the last customer Receipt for other customers Note The fractions are included in the last customer REG C01 10 10 01 12 34 000001 0 01 REG C01 15 12 03 12 34 000001 X 0000025 OPEN CHK MC 01 REG C01 15 12 03 12 50 001190 CHECK No 1328 100 35 MC 01 REG C01 15 12 03 12 55 001195 CHECK No 1330 MC 01 REG C01 15 12 03 12 58 001205 CHECK No 1363 0 01 REG C01 10...

Page 149: ...ssthemedia key to be changed 3 Enter the amount to change and press the media to change until the change amount equals to the changed amount REG C01 10 10 01 12 34 000001 MEDIA CHG REG C01 10 10 01 12 34 000001 MEDIA CHG CASH 10 00 CASH 10 00 10 00 REG C01 10 10 01 12 34 000001 MEDIA CHG CASH 10 00 CHECK 2 00 CHECK 2 00 8 00 REG C01 10 10 01 12 34 000001 MEDIA CHG CASH 10 00 CHECK 2 00 CREDIT 8 00...

Page 150: ...KE OUT 4 13 Scanning PLU This function is used for registering PLU items by scanner or OBR code OBR Before using this function you should allocate the scanning PLU file file no 16 connect ascannerandallocate OBR key functioncode 103 ApplicableOBRcodesareEAN 13 EAN 8 and UPC A To register a scanning PLU item 1 Just scan the item PLU0100 2 Enter the OBR code on the label and press the OBR key Not fo...

Page 151: ...g PLU items to from the scanning PLU file The procedure to perform batch maintenance program to the batch maintenance file first and execute batch maintenance file Refer to 4 4 1 Programming direct maintenance in the programming manual Refer to 4 4 2 Programming batch maintenance in the programming manual Refer to 3 3 18 Execute batch maintenance file in this manual Batch maintenance file file no ...

Page 152: ... time and item quantity The barcode data of the main item should be programmed to the Non PLU table Shop code is programmed to the 48 th record of the general control file Multi EAN link If you want to register an item as the item with different barcode data program the barcode data of the linked item and the parent item to the multi EAN link file file no 075 Refer to 4 4 3 Programming multi EAN l...

Page 153: ...001 level 2 200 PLU0001 SHIFT PLU level2 200 PLU0001 level 3 PLU0001 SHIFT PLU level3 PLU0001 CASH Scanning PLU 1 Register PLU0001 Scan PLU0001 level 2 PLU0001 SHIFT PLU level2 Scan PLU0001 level 3 PLU0001 SHIFT PLU level3 Scan PLU0001 CASH 4 15 Printing barcode on receipts UP 400 and UP 360 This function is used for registering old check by scanning the barcode on the new balance receipt or issui...

Page 154: ...he check number of this receipt and press the NEW OLD key 3 Press ROUND REPEAT to recall the last receipt REG C01 10 10 01 12 34 000001 CHECK No 1111 1 PLU0001 1 00 1 PLU0002 2 00 1 PLU0003 3 00 NEW OLD 1111 3 ST 6 00 REG C01 10 10 01 12 34 000001 CHECK No 1111 1 PLU0001 1 00 1 PLU0002 2 00 1 PLU0003 3 00 SRVC TL 6 00 SRVC TL 6 00 REG C01 10 10 01 12 34 000001 CHECK No 1111 1 PLU0001 1 00 1 PLU000...

Page 155: ...t or rate Coupon random code if coupon type is selected Target item PLU Flat PLU Department Subdepartment bundle quantity 2 Allocate coupon number key if necessary Function code 110 Mix and match type 1 Item registration PLU0001 PLU0002 PLU0003 Discount is performed automatically Coupon type 1 Item registration PLU0011 PLU0012 PLU0013 1234 CPN Discount is performed automatically REG C01 10 10 01 1...

Page 156: ...tomer No and press the CUST customer ID No key 2 Perform item registration You can re enter the customer ID No PLU0001 PLU0002 PLU0003 3 Press the TABLE TRANSFER key to finalize the transac tion Payment by PAYMENT key 1 Press the PAYMENT key 2 Enter customer No and press the CUST customer ID No key 3 Perform a finalize operation Note Pressing the CUST directly shows customer No and name window to ...

Page 157: ...en Youcanselecttheappropriateordercharacterinthewindow If the linking order character record No is set the order character is changed to the linking character automatically 4 21 Item search Before using this function the following programs are necessary 1 Allocating item search key 246 2 Searching range By group subdepartment department and its record No A1 By pressing ITEM SEARCH key the characte...

Page 158: ... discount Discount amount or rate Free item barcode if free item type is selected 2 Programming scanning PLU Scan mix match link Mix and match type 1 Item registration Scanning PLU0001 Scanning PLU0002 Scanning PLU0003 Free item type 1 Item registration Scanning PLU0011 Scanning PLU0012 Scanning PLU0013 Free item is registered automatically REG C01 10 10 01 12 34 000001 1 PLU0011 1 00 1 PLU0012 2 ...

Page 159: ...er of unit interval time upper Change Price After thirdtimeframeunitprice lowerNewIntervalPrice numberofunitintervaltime lower Change Price After and calculation method Use Last Interval Price Time calculation There are two calculation methods In case of setting No to Use Last Interval Price Total fee case A 1 TA Interval time Total fee case B 1 TF Interval time 2 TB TF Interval time Total fee cas...

Page 160: ...dom PLU code or PLU record number character to replace or add on maximum 10 kinds of add on replace add on selection program additional character target device In case of replacing PLU character PLU file character Beef Steak Additional PLU character Bifteck du boeuf Bifteck du boeuf is printed In case of adding on PLU character PLU file character Beef Steak Additional PLU character 1 Bifteck du bo...

Page 161: ...R 161 QT 6600 Reference Manual 5 Refund mode operation R 162 5 1 Selecting REF or REG mode R 162 ...

Page 162: ... RF or REG key to turn that mode Refund registration or register minus REG registration starts with this operation Note Key operations are similar to that in the register mode To avoid miss registration in the REF or REG mode return the mode to the former one immediately REG C01 10 10 01 12 34 000001 REG Mode C01 RF C01 10 10 01 12 34 000001 REFUND Mode C01 R C01 10 10 01 12 34 000001 REG Mode C01...

Page 163: ...R 163 QT 6600 Reference Manual 6 Read and reset operations R 164 6 1 The procedures of reading or resetting R 164 6 2 Report sample R 166 ...

Page 164: ...red to the totalizers and counters 6 1 The procedures of reading or resetting 1 Sign on a clerk if necessary 2 Press MODE and X Z to assign X Z report 3 Select the appropriate menu you want by following the guidances The hierarchy of the X Z menus are described below Refer to page 114 of this manual for X Z command X Z C01 15 12 96 12 34 000000 X Z Report 1 Daily X 2 Periodic 1 X 3 Periodic 2 X 4 ...

Page 165: ...y X only Zero Sales Daily X only NFP scan PLU Daily Z only Inactive Days Report Daily X Z only Scan Mix Match Daily X Z only Others Individual key Daily X Z only Flash Daily X only Fixed totalizer Free Function PLU PLU stock Daily X Z only Sub Department Department Group Hourly sales Monthly sales Table analysis Void Hourly product Mix Match Simple Time Attendance Daily X Z only IDC IDC n clear Z ...

Page 166: ...3 1 GROSS 21 45 00 NET No 5 40 00 CAID 35 00 Cashier report CHID 3 00 CKID 0 00 CRID 0 00 CASH No 10 35 00 C10 1 GROSS 10 18 00 NET No 8 18 00 CAID 15 00 Clerk report CHID 3 00 CKID 0 00 CRID 0 00 CASH No 5 15 00 Individual key Z 0001095 Mode Report code CASH No 11 38 00 Function key descriptor Counter Totalizer CHECK No 0 0 00 CREDIT No 1 12 00 ADD CHK No 0 TL 12 50 00 TL descriptor Counter Total...

Page 167: ...Grand total 2 descriptor Grand total 2 GT3 1325670420 24 Grand total 3 descriptor Grand total 3 000001 001279 Consecutive No range Free function Z 0001012 FREE FUNCTION 123 Mode Report code Report title Z No Z only CASH No 11 38 00 Transaction key descriptor Counter Amount RC No 2 8 00 PD No 1 1 00 PLU Z 0001014 PLU 123 Mode Report code Report title Z No Z only PLU0001 11 2 50 682 55 PLU descripto...

Page 168: ...ISCOUNT 1 00 Discount total can be skipped 0001 68 25 PLU No can be skipped Sales ratio can be skipped PLU0002 25 32 00 DISCOUNT 5 00 0002 3 2 TL 75 714 55 Total by group dept subdept Counter Amount DISCOUNT 6 00 71 45 GROUP02 02 00 PLU0005 1 2 00 Non Group dept subdept link items DISCOUNT 0 00 0005 0 2 TL 1 2 00 DISCOUNT 0 00 0 2 PLU by order character X 4000014 PLU Mode Report code Report title ...

Page 169: ...PLU descriptor Counter Amount DISCOUNT 0 00 0001 PLU No can be skipped PLU0002 0 0 00 GROUP02 02 TL 0 0 00 DISCOUNT 0 00 TL 0 0 00 DISCOUNT 0 00 PLU stock PLU less stock X 0000064 PLU STOCK Mode Report code Report title Z No Z only PLU0001 10 123 45 PLU descriptor Minimum stock level Current stock 0001 PLU No can be skipped PLU0002 25 20 short stock 0002 PLU stock by range X 0010064 PLU STOCK Mode...

Page 170: ...45 TL 151 156 55 DISCOUNT 3 00 100 00 Subdepartment by range X 0010013 SUB DEPT Mode Report code Report title Z No Z only 0001 0002 Range SUBDEPT01 24 82 55 Subdepartment descriptor Counter Amount DISCOUNT 1 00 Discount total can be skipped 70 82 Sales ratio can be skipped SUBDEPT02 25 32 00 DISCOUNT 2 00 27 45 TL 49 114 55 DISCOUNT 3 00 98 27 Subdepartment by group dept X 100013 SUB DEPT Mode Rep...

Page 171: ...n be skipped DEPT02 25 32 00 DISCOUNT 2 00 27 45 TL 49 114 55 DISCOUNT 3 00 98 27 Department by group X 1000015 DEPT Mode Report code Report title Z No Z only GROUP01 01 Group title DEPT01 24 82 55 Department descriptor Counter Amount DISCOUNT 1 00 Discount total can be skipped 70 82 Sales ratio can be skipped DEPT02 25 32 00 DISCOUNT 2 00 27 45 TL 49 114 55 DISCOUNT 3 00 98 27 DEPT04 1 1 00 No gr...

Page 172: ...eport title Z No Z only 7 Day of the month GROSS 52 680 57 Gross counter Gross amount NET No 12 680 50 Net counter Net amount 8 GROSS 78 1 034 59 NET No 37 1 034 57 TL GROSS 130 1 715 16 13 19 Average gross sales NET 49 1 715 07 35 00 Average net sales Table analysis Z 0001028 TABLE ANALYSIS 123 Mode Report code Report title Z No Z only TBL0001 CT 12 680 57 Table No Customer count Net amount AVRG ...

Page 173: ...descriptor entered customer name 1 00 Dummy check CHECK No 003333 NEW OPEN 0 00 Newly opened status TL No 4 360 80 Electronic journal E journal Z 0001058 JOURNAL Mode Report code Report title MC 03 REG C01 07 11 2005 16 34 001029 1 PLU0055 100 00 0 12 0 12 Registrations TL 99 88 CASH 99 88 MC 03 P1 C01 07 11 2005 16 35 001030 Some program are made in Program 1 mode MC 03 X Z C01 07 11 2005 16 37 0...

Page 174: ... is printed in order to clock in the shift If there is the same JOB code then it will add to the JOB that was found before 5 If employee is not clocked out the shift then is printed No JOB is printed if employee is not clocked in the shift 6 You can select HH MM format or HH mm print minutes in fraction format Employee report weekly bi weekly X 000129 EMPLOYEE Mode Report code Report title Z count...

Page 175: ...01 1234 5 1 234 50 20 9 89 6 172 62 TL 62 395 07 Total Amount of all Time frame Hourly labor report Z 0001024 HOURLY LABOR 1234 Mode Report code Report title Z counter Z only 09 00 09 30 No 2 2 469 06 Time frame NET counter NET Amount 82 62 NET ratio can be skipped COST 00 05 0 08 Work time Pay 0 Pay ratio NET SALES HOUR 29 628 72 Proceeds per work time COST TRANSACTION 0 04 Wages per transaction ...

Page 176: ...al BUSY Busy Occupied flag CUST No 000022 BALANCE 110 23 DISCOUNT 1 23 FINALIZED GT 616 36 DISCOUNT GT 41 23 TL No 2 No of customer BALANCE 120 46 Customer balance total DISCOUNT 2 46 Customer discount total Customer open check total only X 0040047 CUSTOMER Mode Report code Report title Z counter Z only TL No 2 No of customer BALANCE 120 46 Customer balance total DISCOUNT 2 46 Customer discount to...

Page 177: ...0 20 05 UNWELL WHOLE TIME 04 35 EMPLOYEE NO 000999 WHOLE TIME 00 00 Scanning PLU with shift file Z 0001026 SCANNING PLU 123 Mode Report code Report title Z No Z only 49177008 OBR code ERASER 1 1 00 Item decriptor Counter Amount 4901351036723 OBR code CANDY 123 012 123 45 Item decriptor Counter Amount 2nd Price 12 12 00 2nd price decriptor Counter Amount 7th Price 1 5 00 7th price decriptor Counter...

Page 178: ...TAL ITEMS 0001234 100000 Items Allocated records Scanning PLU stock by group department subdepartment X 0020026 STOCK REPORT Mode Report code Report title 0001 0010 Range group department subdepartment DEPT01 Group department subdepartment descriptor 4911177008 OBR code ERASER 100 Item decriptor Actual stock 4901351036723 OBR code for 2nd shift CANDY 3 452 Item decriptor Actual stock DEPT02 490210...

Page 179: ... DISCOUNT 10 98 1 22 20 93 2 7 19 29 Scanning PLU zero sales by group department subdepartment X 0060026 ZERO SALES Mode Report code Report title 0001 0010 Range group department subdepartment DEPT01 Group department subdepartment descriptor 4911177008 OBR code ERASER 28 02 2008 Item decriptor Last update date 4901351036723 CANDY 01 03 2008 DEPT02 4902102037549 OOLONG TEA 12 03 2008 Scanning PLU i...

Page 180: ...010027 NOT FOUND PLU Mode Report code Report title C01 Clerk 4911177008 OBR code DEPT01 5 5 00 Link department decriptor Counter Amount DISCOUNT 1 98 Discount total Barcode 4911177008 4901351036723 DEPT01 5 10 00 DISCOUNT 1 77 4901351036723 ...

Page 181: ...R 181 QT 6600 Reference Manual A 1 Function key list R 182 ...

Page 182: ...U nnn F S FSST FSTD FUNCLIST HOUSE BON SEARCH X KETTEN LIST LIST LOAN LOCATION NOP MEDIA CHG MENU MDST X NB NEW CHK NEW OLD NLU NRMRCT NS NS NFP CT OBR OLD CHK OPEN OPEN2 OPEN CHK OPE OPE X Z ORDER CHAR PD Function Code Initial character Payment 149 Pick up 022 Plus 029 PLU 048 Post entry 115 Premium 030 Price 049 Price change 104 Price inquiry 008 Quantity for 083 Recall 131 Receipt 038 Receipt o...

Page 183: ...olidation R 191 A 2 5 5 Batch maintenance R 192 A 2 5 6 Multi EAN link R 192 A 2 5 7 Non PLU table R 192 A 2 5 8 NLU table R 192 A 2 6 Department file R 193 A 2 6 1 Department daily R 193 A 2 6 2 Department periodic consolidation R 193 A 2 7 Group file R 194 A 2 7 1 Group daily R 194 A 2 7 2 Group periodic consolidation R 194 A 2 8 Clerk file R 195 A 2 8 1 Clerk programming R 195 A 2 8 2 Clerk det...

Page 184: ...solidation R 205 A 2 18 Customer file R 206 A 2 18 1 Customer file R 206 A 2 18 2 Customer group file daily R 206 A 2 18 3 Customer group periodic consolidation R 206 A 2 18 4 Customer title R 206 A 2 19 General control file R 207 A 2 19 1 General control R 207 A 2 20 Special character file R 208 A 2 20 1 Special character R 208 A 2 21 Report header file R 208 A 2 21 1 Report header R 208 A 2 22 T...

Page 185: ...4 A 2 40 1 Intelligent EJ file R 214 A 2 41 Menu title character file R 214 A 2 41 1 Menu title character file R 214 A 2 42 Tare table file R 214 A 2 42 1 Tare table file R 214 A 2 43 Screen logo file R 215 A 2 43 1 Screen logo file R 215 A 2 44 Full screen check window 1 3 file R 215 A 2 44 1 Full screen check window 1 3 file R 215 A 2 45 Additional PLU program file R 215 A 2 45 1 Additional PLU ...

Page 186: ...e R 219 A 2 49 11 Keyboard bitmap image R 219 A 2 49 12 TCP IP control R 220 A 2 49 13 FTP Login Name R 220 A 2 49 14 FTP Server Name R 220 A 2 49 15 FTP Trans file R 220 A 2 49 16 Character key table file R 220 A 2 49 17 PS2 key table file R 221 A 2 49 18 Key table full screen file R 221 ...

Page 187: ...t amount 018 Declared over credit amount 019 Food stamp in drawer 020 Food stamp cash change 021 EBT in drawer 022 EBT cash change 023 Refund mode total 024 Customer count 025 Average sales per customer 026 Check cashing service fee 027 New balance fee 028 future use 029 Clerk commission 1 total 030 Clerk commission 2 total Rec No Contents 031 Foreign currency cash in drawer 1 032 Foreign currency...

Page 188: ...bdepartment daily File name Subdepartment daily File No 003 Max allocatable records 99 A 2 3 2 Subdepartment periodic consolidation File name Subdepartment periodic 1 File No 103 Max allocatable records 99 File name Subdepartment periodic 2 File No 203 Max allocatable records 99 File name Subdepartment daily consolidation File No 303 Max allocatable records 99 File name Subdepartment periodic 1 co...

Page 189: ...lidation File No 504 Max allocatable records 9999 File name PLU consolidation work File No 604 Max allocatable records 9999 Counter Totalizer 0 5 10 15 Discount totalizer Weight 20 25 House Bon quantity 30 Stock quantity Character 0 24 34 37 Program 2nd 2nd Q ty Not used Not used 40 Link 46 49 43 Unit stock 50 A 2 4 3 PLU 2nd File name PLU 2nd File No 054 Max allocatable records 9999 Character HAL...

Page 190: ...ile No 655 Max allocatable records 9999 Unit price shift 2 Unit price shift 3 Unit price shift 4 Unit price shift 5 Unit price shift 6 Unit price shift 7 Unit price shift 8 Link 2 8 PGM2 8 Counter shift 2 Totalizer shift 2 0 6 9 3 15 18 12 21 42 49 54 59 Counter shift 3 Totalizer shift 3 64 119 69 Counter shift 4 Totalizer shift 4 74 79 Counter shift 5 Totalizer shift 5 84 89 Counter shift 6 Total...

Page 191: ...Scan Mix match daily File No 056 Max allocatable records 99 A 2 5 4 Scan Mix match periodic consolidation File name Scan Mix match periodic 1 File No 156 Max allocatable records 99 File name Scan Mix match periodic 2 File No 256 Max allocatable records 99 File name Scan Mix match daily consolidation File No 356 Max allocatable records 99 File name Scan Mix match periodic 1 consolidation File No 45...

Page 192: ...er PGM 23 26 31 39 34 37 38 A 2 5 7 Non PLU table File name Non PLU table file File No 976 Max allocatable records 999 0 Program 5 A 2 5 8 NLU table File name NLU table file File No 077 Max allocatable records 999 0 OBR code File 076 rec 12 6 A 2 5 6 Multi EAN link File name Multi EAN link file File No 075 Max allocatable records 100000 0 OBR code OBR code Parent Link item item 12 6 ...

Page 193: ...artment PLU 2nd Refer to the Elementary program on page 199 of the programming manual Link field for PLU subdepartment department PLU 2nd Refer to the Field 11 066 on page 200 of the programming manual Random code field for PLU department Refer to the Field 12 066 on page 200 of the programming manual Set menu link field for PLU Refer to the Field 13 066 on page 200 of the programming manual Unit ...

Page 194: ...able records 99 File name Group periodic 2 File No 206 Max allocatable records 99 File name Group daily consolidation File No 306 Max allocatable records 99 File name Group periodic 1 consolidation File No 406 Max allocatable records 99 File name Group periodic 2 consolidation File No 506 Max allocatable records 99 File name Group consolidation work File No 606 Max allocatable records 99 Character...

Page 195: ... manual Function control 2 Refer to the Record 05 067 on page 190 of the programming manual Function control 3 Refer to the Record 06 067 on page 191 of the programming manual Function control 4 Refer to the Record 07 067 on page 192 of the programming manual Function control 5 Refer to the Record 08 067 on page 193 of the programming manual Arrangement control Refer to the Record 09 067 on page 1...

Page 196: ...e No 311 Max allocatable records 9801 File name Clerk detail periodic 1 consolidation File No 411 Max allocatable records 9801 File name Clerk detail periodic 2 consolidation File No 511 Max allocatable records 9801 File name Clerk detail consolidation work File No 611 Max allocatable records 9801 A 2 8 3 Clerk detail link File name Clerk detail link File No 030 Max allocatable records 99 Counter ...

Page 197: ...atable records 96 A 2 10 Monthly sales file A 2 10 1 Monthly sales daily periodic consolidation File name Monthly sales daily File No 010 Max allocatable records 32 fixed File name Monthly sales periodic 1 File No 110 Max allocatable records 32 fixed File name Monthly sales periodic 2 File No 210 Max allocatable records 32 fixed File name Monthly sales daily consolidation File No 310 Max allocatab...

Page 198: ... 1920 File name Hourly Item periodic 1 consolidation File No 421 Max allocatable records 1920 File name Hourly Item periodic 2 consolidation File No 521 Max allocatable records 1920 File name Hourly Item consolidation work File No 621 Max allocatable records 1920 A 2 11 2 Hourly item link Hourly production link File name Hourly item link File No 031 Max allocatable records 480 Totalizer 0 5 Counte...

Page 199: ...nd match periodic 1 consolidation File No 451 Max allocatable records 99 File name Mix and match periodic 2 consolidation File No 551 Max allocatable records 99 File name Mix and match consolidation work File No 651 Max allocatable records 99 Character 0 16 19 22 Discount amount or rate Random code Rec No File No Quantity Comb 1 item 41 40 38 Rec No File No Quantity Comb 2 item 46 45 43 Rec No Fil...

Page 200: ... name IDC 2 consolidation work File No 658 Max allocatable records 100000 File structure is same as IDC file 1 A 2 13 3 IDC file 3 File name IDC 3 File No 059 Max allocatable records 100000 File name IDC 3 daily consolidation File No 359 Max allocatable records 100000 File name IDC 3 consolidation work File No 659 Max allocatable records 100000 File structure is same as IDC file 1 Refer to the pag...

Page 201: ...Correspond to 6th day of the week of Employee Rec 001 First week Rec 019 021 Correspond to 7th day of the week of Employee Rec 001 First week Rec 020 024 Correspond to 1st day of the week of Employee Rec 001 Second week Rec 025 027 Correspond to 2nd day of the week of Employee Rec 001 Second week Rec 028 030 Correspond to 3rd day of the week of Employee Rec 001 Second week Rec 031 033 Correspond t...

Page 202: ...Employee File No 801 Max allocatable records 99 Refer to page 62 of the programming manual for details A 2 14 5 Job code file File name Job code File No 802 Max allocatable records 50 Refer to page 61 of the programming manual for details 0 3 Employee No 19 Social Security No Job code 1 PGM 24 252627 Job code 2 Job code 3 Job code 4 Clerk No Work 1 Work 2 Work 3 282930 32 34 36 Character End time ...

Page 203: ...ee Rec 001 Rec 006 Correspond to 2nd day of the week Shift 3 of Employee Rec 001 Rec 021 Correspond to 7th day of the week Shift 3 of Employee Rec 001 Rec 022 Correspond to 1st day of the week Shift 1 of Employee Rec 002 Rec 023 Correspond to 1st day of the week Shift 2 of Employee Rec 002 Rec 024 Correspond to 1st day of the week Shift 3 of Employee Rec 002 Rec 025 Correspond to 2nd day of the we...

Page 204: ...ax allocatable records 99 A 2 16 Table analysis file A 2 16 1 Table analysis daily File name Table analysis daily File No 018 Max allocatable records 99 A 2 16 2 Table analysis periodic consolidation File name Table analysis periodic 1 File No 118 Max allocatable records 99 File name Table analysis periodic 2 File No 218 Max allocatable records 99 File name Table analysis daily consolidation File ...

Page 205: ...ed File name Grand total periodic 2 File No 220 Max allocatable records 3 fixed File name Grand total daily consolidation File No 320 Max allocatable records 3 fixed File name Grand total periodic 1 consolidation File No 420 Max allocatable records 3 fixed File name Grand total periodic 2 consolidation File No 520 Max allocatable records 3 fixed File name Grand total consolidation work File No 620...

Page 206: ...stomer group periodic 2 consolidation File No 542 Max allocatable records 20 File name Customer group consolidation work File No 642 Max allocatable records 20 A 2 18 4 Customer title File name Customer title File No 123 Max allocatable records 9 Customer number Customer name Customer address 1 0 55 Customer address 2 79 Customer address 3 103 Customer address 4 127 133 6 31 7 Title link Customer ...

Page 207: ...17 Receipt control 3 Calculation method 163 018 Slip Guest receipt control 164 019 Journal control Electronic journal 165 020 Message print control 165 021 Order control 1 166 022 Hotel server 167 023 Australian GST control 1 167 024 Australian GST control 2 Loyalty card 167 025 Set menu Condiment 167 026 Check tracking 168 027 Clerk interrupt 169 028 Display control 169 029 not used 030 Order con...

Page 208: ...ial character File No 023 Max allocatable records 99 fixed Character 0 16 Refer to page 134 of the programming manual for details Refer to page 135 of the programming manual for details A 2 22 Tax table file A 2 22 1 Tax table File name Tax table File No 025 Max allocatable records 10 Actual value Rate Max Table amount Rounding 0 74 4 6 7 Singapore rounding 8 Cal type Cyclic pattern Cyclic value N...

Page 209: ...ecord No 10 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 Record No 11 Record No 12 Record No 13 Record No 14 Record No 15 Record No 16 Record No 17 Record No 18 File No 11 File No 12 File No 13 File No 15 File No 16 File No 17 File No 18 Record No 19 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 Record No 20 File No 19 File No 20 76 78 80 File No 10 File No 14 Character Record No...

Page 210: ...de 7 0 1 2 3 4 5 6 7 8 9 10 X Z code 8 A 2 26 Receipt Slip message file A 2 26 1 Receipt Slip message File name Receipt Slip message File No 032 Max allocatable records 96 A 2 27 Check endorsement message file A 2 27 1 Check endorsement message File name Check endorsement message File No 033 Max allocatable records 4 Character 0 40 Character 0 40 Refer to page 132 of the programming manual for det...

Page 211: ...table records 9999 File name Arrangement group 5 File No 438 Max allocatable records 9999 Arrange character 0 24 A 2 29 Character recall file A 2 29 1 Character recall File name Character recall File No 039 Max allocatable records 9999 A 2 30 Check print file A 2 30 1 Check print File name Check print File No 041 Max allocatable records 9 A 2 31 Graphic logo file A 2 31 1 Graphic logo external pri...

Page 212: ...A 2 33 Order character file A 2 33 1 Order character File name Order character File No 065 Max allocatable records 99 A 2 34 Euro program file A 2 34 1 Euro program file File name Euro program File No 099 Max allocatable records 3 fixed Program 0 4 Refer to page 181 of the programming manual for details A 2 35 Character conversion for CF file A 2 35 1 Character conversion for CF file File name Cha...

Page 213: ...al for details A 2 38 Sound file A 2 38 1 Sound 1 10 file File name Sound 1 File No 701 Max allocatable records 65000 File name Sound 2 File No 702 Max allocatable records 65000 File name Sound 3 File No 703 Max allocatable records 65000 File name Sound 4 File No 704 Max allocatable records 65000 File name Sound 5 File No 705 Max allocatable records 65000 File name Sound 6 File No 706 Max allocata...

Page 214: ...elligent EJ file File name Intelligent EJ File No 050 Max allocatable records 100000 Data 0 101 Character 0 40 A 2 41 Menu title character file A 2 41 1 Menu title character file File name Menu title character File No 085 Max allocatable records 60 A 2 42 Tare table file A 2 42 1 Tare table file File name Tare table File No 127 Max allocatable records 9 Character PGM 0 16 22 ...

Page 215: ...n check window File No 797 798 799 Max allocatable records 9833 fixed Bipmap 0 160 A 2 45 Additional PLU program file A 2 45 1 Additional PLU program file File name Additional PLU program File No 814 Max allocatable records 9999 Program not used Color Link Price 2 Price 3 Work 0 7 9 12 15 44 46 A 2 46 External device serial number file A 2 46 1 External device serial number file File name External...

Page 216: ...al PLU character file File name Additional PLU character File No 941 Max allocatable records 9999 PLU code Character PGM 0 7 31 32 A 2 48 Free function list file A 2 48 1 Free function list file File name Free function list File No 946 Max allocatable records 99 Rec No 0 2 ...

Page 217: ... program value Master 01 Backup master 02 Self master 03 Satellite 00 Check tracking master backup master current value Master 01 Backup master 02 Self master 03 Satellite 00 Always 00000 Check tracking cluster number 0 9 0 means no designation IP address 192 168 0 0 192 168 255 255 Significant characters Significant numbers Significant numbers Significant numbers Significant number D24 D23 D22 D2...

Page 218: ...ction table File name Printer connection table File No 903 Max allocatable records 99 A 2 49 7 Auto program control File name Auto program control File No 905 Max allocatable records 20 File No Program 0 2 3 Refer to page 65 of the programming manual for details A 2 49 8 Screen color control File name Screen color control File No 906 Max allocatable records 99 Refer to page 66 of the programming m...

Page 219: ... bitmap image for single key File No 909 Max allocatable records 29400 File name Keyboard bitmap image File No 910 Max allocatable records 93600 Program 0 9 Program 0 9 Data 0 200 Bitmap file in case of creating by PC 1 Windows bitmap file 2 Max 16 77 million color 3 Key size Rectangular key Circular key Key area Check clerk window File 909 Single key 66 x 52 72 x 58 84 x 74 92 x 77 Single key 66 ...

Page 220: ... for details A 2 49 15 FTP Trans file File name FTP trans file File No 913 Max allocatable records 99 Refer to page 73 of the programming manual for details A 2 49 16 Character key table file File name Character key table File No 274 Max allocatable records 152 fixed Program 0 6 Password Login ID 0 10 20 IP address Login ID Server title not used 0 20 46 26 62 Password Login folder name 78 98 File ...

Page 221: ...een File No 795 Max allocatable records 240 0 4 2 Function code Location X1 Location Y1 Location X2 Location Y2 Location X1 Y1 Key Location X2 Y2 Key type binary Key Keytop text 1 Keytop text 2 color RGB 6 8 10 11 not used 21 14 Text color RGB 17 Check rec 20 not used 42 62 41 Rec 001 080 Full screen check window 1 Rec 081 160 Full screen check window 2 Rec 161 240 Full screen check window 3 Key t...

Page 222: ...R 222 File Format ...

Page 223: ...R 223 QT 6600 Reference Manual A 3 Counter and Totalizer calculation method R 224 A 3 1 Fixed totalizer file R 224 ...

Page 224: ... for sale For REG mode 1 is affected Amount at the finalization exclude tip Department Subdepartment PLU Scan PLU product registration amounts non full hash Last item void amounts for the above Item return amounts for the above Previous item void amounts for the above Cancel amounts for the above Plus key Premium key Error correction amounts Cancel amounts Minus key Discount key Coupon Error corre...

Page 225: ...rate or flat fee Entered amount in foreign currency Registered amount of Minus key Registered item amount by RF Void key 1 REG REF REG mode When the CLEAR key is pressed Fraction amount by country roundings Void total of ST transfer Subtotal of taxable amount at finalization of sale in case of add on tax Subtotal of taxable amount 1 VAT rate at finalization of sale in case of add in tax Result of ...

Page 226: ...R 226 Calculation method ...

Page 227: ...R 227 QT 6600 Reference Manual A 4 Error messages R 228 A 4 1 Error messages R 228 A 4 2 Operation prompt R 231 A 4 3 System error code R 232 ...

Page 228: ...y Change amount exceeds the limit Contents of the drawer exceed the programmed limit Sentinel function H D L H A L L D L error Money declaration compulsory Guest receipt compulsory Validation compulsory Check print compulsory Check endorsement compulsory Registration buffer full Slip compulsory Alarm when no paper is inserted in the Slip Check tracking index full near end Check tracking memory ful...

Page 229: ...y E134 Middle of Clerk Transfer Press ESC Key Printer downed means ECR logical ID and printer number Paper near end end means ECR logical ID and printer number Paper near end end means ECR logical ID and printer number Print buffer full at sender side Down at target ECR which has printer means ECR logical ID and printer number Printer buffer full at target ECR which has printer means ECR logical I...

Page 230: ...k There is no available shift left Employee attempts to operate CLOCK OUT whilst he she is in a break time Break hours are exceeded Employee is at work without break Employee who has not done BREAK OUT operation attempts to operate BREAK IN Sign on after you clock in or break out Employee Report has not been reset Time Attendance Data communication error IDC FILE 1 memory is full of items IDC FILE...

Page 231: ... Confirmation to reset displayed report Confirmation of all void operation Please wait ECR now processing In the item consolidation mode Not in the item consolidation mode Mode change REG mode Mode change REF mode Mode change REG mode Signing on a training operator Mode change REG2 mode The terminal is in signed off CHK compulsory TBL compulsory Covers compulsory Seat compulsory Slip compulsory GU...

Page 232: ... CMD 0049 Illegal command No Not DATA 0050 Sequence error 0051 Turn off DSR signal 0052 Received cancellation 0053 Retry over while waiting command 0054 Retry over while waiting EOT 0055 Retry over while waiting data 0056 Received EOT 0057 Retry over while waiting ACK 0058 Retry over while sending data 0059 Retry over while waiting C 0060 Retry over while sending response 0061 Retry over while exc...

Page 233: ...7 Error during termination 0168 Error when resource return 0170 Error during getting task ID 0171 No code is found while search pick up 0172 Cannot get work buffer 0173 File opened fail to activate task 0174 No file exists 0175 ITRON service error 0176 Cannot create file 0177 Record number error 0178 Detect error while memory area opening 0179 Detect error while returning mail box double create er...

Page 234: ...R 234 Error messages ...

Page 235: ...49 P 98 P 175 check tender R 30 R 182 P 25 check tracking R 17 R 44 P 46 check window P 68 P 182 check pop up window definition R 213 check popup window definition P 22 circular key P 26 clear key R 29 R 182 clerk R 12 R 166 R 195 P 20 clerk i Button key ID P 20 clerk control P 75 P 81 clerk detail R 49 R 196 P 20 P 86 P 197 clerk detail link R 196 P 20 clerk feature P 185 clerk interrupt R 17 R 4...

Page 236: ... 171 R 182 R 193 P 18 P 25 P 130 P 141 P 142 P 147 P 148 P 198 department number R 37 R 182 P 25 department totalizer R 24 deposit R 31 R 182 P 25 P 101 direct maintenance R 151 P 123 discount R 31 R 182 P 25 P 102 display R 13 display area color definition P 18 display buffer P 21 display control P 47 display mode R 38 R 182 P 25 display on off key R 10 R 29 double key P 26 double size letter key...

Page 237: ... R 32 R 182 P 25 P 104 non add no sale R 32 R 182 P 25 P 104 normal receipt R 31 R 182 P 25 Norwegian rounding P 35 not found PLU R 180 R 182 P 25 number look up R 182 P 25 P 124 number of customer R 32 R 182 P 25 P 105 numeric key R 29 R 182 O OBR R 36 R 182 P 25 old check R 36 R 182 P 25 P 112 online P 55 open R 34 R 182 P 25 P 107 open 2 P 25 P 107 open check R 37 R 148 R 173 R 182 P 25 P 109 o...

Page 238: ...P 22 scroll area R 12 seat number R 37 R 182 P 25 second unit price R 34 R 182 P 25 selective item subtotal R 35 R 182 P 25 P 109 self master R 17 separate check R 36 R 147 R 182 P 25 set menu R 143 R 144 R 209 P 21 P 33 P 45 P 151 shared check tracking R 44 shift key P 126 shift PLU R 34 R 153 R 167 R 177 R 182 R 190 P 20 P 25 P 112 P 118 P 143 sign off reason P 138 sign on R 68 sign on off R 138...

Page 239: ...1 P 72 P 184 terminal file R 23 text print R 30 R 182 P 25 P 97 text recall R 30 R 182 P 25 P 97 P 132 P 148 time attendance R 58 P 20 P 61 time calculation R 159 time zone R 202 P 20 P 60 P 177 tip R 31 R 182 P 25 P 99 touch screen key table R 217 P 18 touch screen panel R 10 transaction key R 188 R 191 P 18 tray total R 34 R 182 P 25 P 113 two zero R 182 U U S tax P 35 up arrow R 182 UP 360 R 16...

Page 240: ...CASIO COMPUTER CO LTD 6 2 Hon machi 1 chome Shibuya ku Tokyo 151 8543 Japan MA0901 00501A Printed in Japan QT 6600REF E c ...