![background image](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343089.webp)
62
Wiring
Section 3-4
Wiring
Connector on Servo Drive End
Connector Plug: 10126-300VE (Sumitomo 3M)
Connector Case: 10326-52A0-008 (Sumitomo 3M)
Connector on Connector Terminal Block End
Connector Socket: XG4M-2030 (OMRON)
Strain Relief: XG4T-2004 (OMRON)
Cable: AWG28
×
3P + AWG28
×
7C UL2464
Note
Signal names for the connector on the Servo Drive end are for standard I/O
allocations.
Connector Terminal Block
Cable (XW2Z-
@
J-B19)
This is the Connector Terminal Block Cable for the SMARTSTEP Junior Servo
Drive Control I/O Connector (CN1).
Standard Cables
Connection Configuration and Dimensions
Connector terminal block end
Name
+24 V
0 V
+24 V
0 V
+24 V
0 V
DEC
POT
NOT
EXT1
EXT2
EXT3
BATGND
BAT
BKIRCOM
BKIR
ALMCOM
ALM
FG
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Servo Drive end
Name
+24 VIN
DEC
POT
NOT
EXT1
EXT2
EXT3
BATGND
BAT
BKIRCOM
BKIR
ALMCOM
ALM
FG
No.
6
9
7
8
10
11
12
15
14
2
1
4
3
Shell
Model
Length (L)
Outer diameter of cable
Approx. weight
XW2Z-100J-B19
1 m
8 dia.
0.1 kg
XW2Z-200J-B19
2 m
0.2 kg
39
29.5
t=12.7
6
L
XW2B-20G4
XW2B-20G5
XW2D-20G6
R7D-Z
@
Connector terminal
block end
Servo Drive end
Summary of Contents for CJ1W-MA - REV 10-2008
Page 3: ...iv ...
Page 5: ...vi ...
Page 21: ...xxii ...
Page 57: ...30 Starting Operation Section 2 2 ...
Page 97: ...70 Wiring Section 3 4 ...
Page 247: ...220 Transferring Servo Parameters Section 5 3 ...
Page 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Page 343: ...316 Absolute Encoder Origin Section 8 6 ...
Page 375: ...348 Linear Interpolation Section 9 7 ...
Page 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Page 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 641: ...614 Index ...
Page 643: ...616 Revision History ...