![Omron CJ1W-MA - REV 10-2008 Operation Manual Download Page 552](http://html1.mh-extra.com/html/omron/cj1w-ma-rev-10-2008/cj1w-ma-rev-10-2008_operation-manual_742343552.webp)
525
List of Parameters
Appendix B
Pn511
Input sig-
nal selec-
tion 5
2
1
EXT1 signal
input terminal
allocation
0 to 3
Always disabled.
8
---
---
Offline
Stan-
dard
setting:
4
4
Allocated to CN1,
pin 44: Valid for low
input
5
Allocated to CN1,
pin 45: Valid for low
input
6
Allocated to CN1,
pin 46: Valid for low
input
7
Always enabled.
8
Always disabled.
9 to C
Always disabled.
D
Allocated to CN1,
pin 44: Valid for
high input
E
Allocated to CN1,
pin 45: Valid for
high input
F
Allocated to CN1,
pin 46: Valid for
high input
2
EXT2 signal
input terminal
allocation
0 to F
Same as Pn511.1
8
---
---
Offline
Stan-
dard
setting:
5
3
EXT3 signal
input terminal
allocation
0 to F
Same as Pn511.1
8
---
---
Offline
Stan-
dard
setting:
6
Pn512
Output sig-
nal reverse
2
0
Output signal
reverse for
CN1 pins 25,
26
0
Not reversed.
0
---
---
Offline
---
1
Reversed.
1
Output signal
reverse for
CN1 pins 27,
28
0, 1
Same as above
0
---
---
Offline
---
2
Output signal
reverse for
CN1 pins 29,
30
0, 1
Same as above
0
---
---
Offline
---
3
Not used.
---
(Do not change the
setting.)
0
---
---
---
---
Pn513
Input sig-
nal selec-
tion 6
2
0
Not used.
8
(Do not change the
setting.)
8
---
---
---
---
1
Not used.
8
(Do not change the
setting.)
8
---
---
---
---
2
Not used.
0
(Do not change the
setting.)
0
---
---
---
---
3
Not used.
0
(Do not change the
setting.)
0
---
---
---
---
Pn51A
Motor-load
deviation
over level
2
Sets the allowable range for the number of pulses for
fully-closed encoders and semi-closed encoders.
0
Pulse
0 to
32767
Online
---
Pn51B
Not used.
---
(Do not change the setting.)
100
---
---
---
---
Pn51C
Not used.
---
(Do not change the setting.)
450
---
---
---
---
Pn51E
Deviation
counter
overflow
warning
level
2
Sets the detection level for the deviation counter over-
flow warning.
0
%
0 to 100 Online
---
Param-
eter No.
Parame-
ter name
Param-
eter
size
Contents
Default
setting
Unit
Setting
range
Enable
setting
Details
Digit
No.
Name
Set-
ting
Explanation
Summary of Contents for CJ1W-MA - REV 10-2008
Page 3: ...iv ...
Page 5: ...vi ...
Page 21: ...xxii ...
Page 57: ...30 Starting Operation Section 2 2 ...
Page 97: ...70 Wiring Section 3 4 ...
Page 247: ...220 Transferring Servo Parameters Section 5 3 ...
Page 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Page 343: ...316 Absolute Encoder Origin Section 8 6 ...
Page 375: ...348 Linear Interpolation Section 9 7 ...
Page 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Page 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 641: ...614 Index ...
Page 643: ...616 Revision History ...