190
Axis Operating Input Memory Areas
Section 4-8
Stop Execution Flag
Word
b
Bit
15
Function
This flag turns ON in response to a DECELERATION STOP or EMERGENCY
STOP execution regardless of the axis operation status. If DECELERATION
STOP or EMERGENCY STOP is executed during axis operation, the Stop
Execution Flag turns ON when the command position reaches the target
(stop) position (i.e., when sending the command to the Servo Drive is com-
pleted) regardless of the axis feedback position.
This flag then turns OFF when the power is turned ON, a connection is
released, or when another axis operation is started.
Details
Refer to
10-9 Stop Functions
.