253
Standard Settings for Servo Drives Using MECHATROLINK
Section 6-4
Note
The PCU uses the forward drive inhibit input, reverse drive inhibit input, and
origin proximity input allocated in the Servo Drive’s external inputs as the for-
ward rotation
limit input signal, reverse rotation limit input signal, and origin
proximity input signal, respectively. Make sure that these input signals main-
tain a signal width no shorter than the MECHATROLINK communications
cycle. If the input signal width is shorter than the communications cycle, the
PCU is unable to detect the input signals, and operations cannot be per-
formed normally.
1
2
3
4
6
7
12
13
EXT1
DEC
NOT
POT
STOP
0GND
ALM
BKIR
I/O Signal Allocations (Default Settings)
R7D-ZN
@
-ML2
CN1