181
Axis Operating Input Memory Areas
Section 4-8
Input
(PCU
to CPU
Unit)
b
06
Axis Con-
trol Status
Flags
No Origin Flag
ON when the origin is not
established.
4-8-3 Axis Control
Status Flags
8-2 Origin Search
Operation
8-3 Present Position
Preset
07
Origin Stop Flag
ON when the present position
of the axis is stopped within
the origin range set in
Zero
Point Width
.
4-8-3 Axis Control
Status Flags
8-2 Origin Search
Operation
08 to 10
Not used (reserved
by the system).
Always 0.
---
11
Warning Flag
ON when an axis warning has
occurred.
12-1 Overview of
PCU Errors
12
Error Flag
ON when an axis error has
occurred.
13
Busy Flag
ON during axis operation or
processing.
4-8-3 Axis Control
Status Flags
14
Servo Parameter
Transferring Flag
ON during transfer of Servo
Parameters.
5-3 Transferring
Servo Parameters
15
Stop Execution Flag
ON when axis operation is
stopped in response to
EMERGENCY STOP or
DECELERATION STOP.
4-8-3 Axis Control
Status Flags
10-9 Stop Functions
I/O
Word
Bits
Category
Name
Function
Details
Summary of Contents for CJ1W-MA - REV 10-2008
Page 3: ...iv ...
Page 5: ...vi ...
Page 21: ...xxii ...
Page 57: ...30 Starting Operation Section 2 2 ...
Page 97: ...70 Wiring Section 3 4 ...
Page 247: ...220 Transferring Servo Parameters Section 5 3 ...
Page 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Page 343: ...316 Absolute Encoder Origin Section 8 6 ...
Page 375: ...348 Linear Interpolation Section 9 7 ...
Page 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Page 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 641: ...614 Index ...
Page 643: ...616 Revision History ...