546
List of Parameters
Appendix B
Pn511
Input sig-
nal selec-
tions 5
2
1
EXT1 signal
input termi-
nal allocation
0 to 3
Always disabled.
4
---
---
Offline
Stan-
dard
setting:
4
4
Allocated to CN1,
pin 10: Valid for low
input
5
Allocated to CN1,
pin 11: Valid for low
input
6
Allocated to CN1,
pin 12: Valid for low
input
7
Always enabled.
8
Always disabled.
9 to C
Always disabled.
D
Allocated to CN1,
pin 10: Valid for
high input
E
Allocated to CN1,
pin 11: Valid for
high input
F
Allocated to CN1,
pin 12: Valid for
high input
2
EXT2 signal
input termi-
nal allocation
0 to F
Same as Pn511.1
5
---
---
Offline
Stan-
dard
setting:
5
3
EXT3 signal
input termi-
nal allocation
0 to F
Same as Pn511.1
6
---
---
Offline
Stan-
dard
setting:
6
Pn512
Output sig-
nal reverse
2
0
Output signal
reverse for
CN1 pins 1,
2
0
Not reversed.
0
---
---
Offline
---
1
Reversed.
1
Output signal
reverse for
CN1 pins 23,
24
0, 1
Same as above
0
---
---
Offline
---
2
Output signal
reverse for
CN1 pins 25,
26
0, 1
Same as above
0
---
---
Offline
---
3
Not used.
0
(Do not change the
setting.)
0
---
---
---
---
Pn513
Not used.
---
(Do not change the setting.)
0321
---
---
---
---
Pn515
Not used.
---
(Do not change the setting.)
8888
---
---
---
---
Pn51B
Not used.
---
(Do not change the setting.)
1000
---
---
---
---
Pn51E
Deviation
counter
overflow
warning
level
2
Sets the detection level for the deviation counter
overflow warning.
100
%
10 to 100
Online
---
Pn520
Deviation
counter
overflow
level
4
Sets the deviation counter overflow alarm detection
level.
262144
Com-
mand
unit
1 to
1073741823
Online
---
Pn522
Position-
ing com-
pleted
range 1
4
Setting range for positioning completed range 1
(INP1)
3
Com-
mand
unit
0 to
1073741823
Online
---
Pn524
Position-
ing com-
pleted
range 2
4
Setting range for positioning completed range 2
(INP2)
3
Com-
mand
unit
1 to
1073741823
Online
---
Param-
eter No.
Parame-
ter name
Param-
eter
size
Contents
Default
setting
Unit
Setting
range
Enable
setting
Details
Digit
No.
Name
Set-
ting
Explanation
Summary of Contents for CJ1W-MA - REV 10-2008
Page 3: ...iv ...
Page 5: ...vi ...
Page 21: ...xxii ...
Page 57: ...30 Starting Operation Section 2 2 ...
Page 97: ...70 Wiring Section 3 4 ...
Page 247: ...220 Transferring Servo Parameters Section 5 3 ...
Page 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Page 343: ...316 Absolute Encoder Origin Section 8 6 ...
Page 375: ...348 Linear Interpolation Section 9 7 ...
Page 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Page 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 641: ...614 Index ...
Page 643: ...616 Revision History ...