Handling Precautions
Section 13-3
Required Inspection Tools
The following tools, materials, and equipment are required for performing
inspections.
• Voltage tester or digital voltage meter
• Industrial alcohol and a clean cotton cloth
The following measuring devices may be required when performing an
inspection.
• Oscilloscope
• Memory recorder
• Thermometer
• Hygrometer
13-3 Handling Precautions
• Turn OFF the power before replacing the PCU.
• If a PCU is found to be faulty and is replaced, also check the new PCU to
make sure that there are no errors.
• When returning a faulty PCU for repair, make a detailed record of the
PCU's malfunction and take it together with the PCU to your nearest
OMRON office or sales representative.
• If a contact is faulty, clean the contact by applying some industrial alcohol
to a clean cotton cloth and wiping the surface, and then install the PCU.
13-4 Procedure for Replacing a PCU
Use the following procedure when it is necessary to replace a PCU due to
malfunction or other cause. The method for backing up data saved in the
PCU's internal flash memory is also provided here.
13-4-1 Procedure for Replacing a PCU
Use the following procedure to replace a PCU.
1,2,3...
1.
Make a note of the unit number of the PCU to be replaced.
2.
Use the READ DATA Bit to read the parameters saved in the PCU to be
replaced to the PLC's DM Area first. Then save the DM Area data to a flop-
py disk or hard disk using, for example, CX-Programmer. Alternatively, use
the CPU Unit's simple backup function or the PCU's backup function to
back up (write) the PCU parameter data to the Memory Card installed in
the CPU Unit.
3.
Turn OFF the power to the CPU Unit.
4.
Disconnect the MECHATROLINK-II communications cables that are con-
nected to the Servo Drive.
5.
Replace the PCU and reconnect the MECHATROLINK-II communications
cables, making sure that they are securely locked.
6.
Set the unit number for the PCU.
7.
Turn ON the power supply to the CPU Unit.
Summary of Contents for CJ1W-MA - REV 10-2008
Page 3: ...iv ...
Page 5: ...vi ...
Page 21: ...xxii ...
Page 57: ...30 Starting Operation Section 2 2 ...
Page 97: ...70 Wiring Section 3 4 ...
Page 247: ...220 Transferring Servo Parameters Section 5 3 ...
Page 281: ...254 Standard Settings for Servo Drives Using MECHATROLINK Section 6 4 ...
Page 343: ...316 Absolute Encoder Origin Section 8 6 ...
Page 375: ...348 Linear Interpolation Section 9 7 ...
Page 423: ...396 DEVIATION COUNTER RESET Section 10 10 ...
Page 631: ...604 Additional Functions for the CJ1W NCF71 MA Appendix F ...
Page 641: ...614 Index ...
Page 643: ...616 Revision History ...