![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 700](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_1961645700.webp)
9 ACP Measurement
Meas
Notes
Option FP2 is required.
Initial S/W Revision
A.14.00
Define Fast Power Measurement (Remote Command Only)
Fast Power acquisitions are configured using the DEFine command. This command accepts a comma-
delimited string of configuration parameters and their appropriate values, which are all specified in the
subsection below.
Mode
All
Remote Command
:CALCulate:FPOWer:POWer[1,2,…,999]:DEFine "configuration string"
Example
:CALC:FPOW:POW1:DEF "CenterFrequency=2e9, AcquisitionTime=0.005"
Notes
See below for a list of measurement variables that can be defined in the configuration string.
Initial S/W Revision
A.14.00
Acquisition Time
Example
CALC:FPOW:POW1:DEF "AcquisitionTime=0.002"
Notes
The acquisition time parameter sets the time in which the entire spectrum is measured. An increase in the
acquisition time yields an improvement in measurement repeatability.
Preset
0.001 s
Range
0 s to 1 s
Default Unit
Time (s)
Initial S/W
Revision
A.14.00
Center Frequency
Example
CALC:FPOW:POW1:DEF "CenterFrequency=2e9"
Notes
The center frequency parameter sets the frequency in which the measurement is centered around. The
OffsetFrequency parameter is calculated relative to the center frequency.
Preset
1 GHz
Range
0 Hz to maximum instrument frequency
Default Unit
Frequency (Hz)
Initial S/W
Revision
A.14.00
700
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...