![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 1647](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616451647.webp)
12 Code Domain Measurement
AMPTD Y Scale
Long Demod View Symb Power Window Y Ref Value
Sets the absolute power reference value for the code domain power view of the Demod Bits (Long mode)
function in the CDP window.
Key Path
AMPTD Y Scale
Mode
WCDMA
Remote Command
:DISPlay:CDPower:VIEW6:WINDow[1]:TRACe:Y[:SCALe]:RLEVel <real>
:DISPlay:CDPower:VIEW6:WINDow[1]:TRACe:Y[:SCALe]:RLEVel?
Example
DISP:CDP:VIEW6:WIND:TRAC:Y:RLEV 1.0
DISP:CDP:VIEW6:WIND:TRAC:Y:RLEV?
Notes
Target window to control depends on the SubOpCode.
Couplings
When
is set to On, this value is automatically determined by the
measurement result. When you set this value manually, Auto Scaling automatically changes to Off.
Preset
0.00
State Saved
Saved in instrument state.
Min
–250.0
Max
250.0
Initial S/W Revision
Prior to A.02.00
Range
This key is only available when I/Q is the selected input. It replaces the Attenuation key in that case.
Each input channel (I and Q) has four internal gain ranges. The maximum allowed voltage in each gain
range is slightly more than the nominal value, so the break point between ranges is a couple of millivolts
higher than the nominal (setting a peak voltage of 0.502 mV will still map to the 0.5 V Peak range).
Gain Setting
Volts RMS
Volts Peak
Volts Peak - Peak
dBm (50
Ω
)
Break Point
0 dB
0.7071
1.0
2.0
10
n/a
6 dB
0.3536
0.5
1.0
4
0.502 V Peak
12 dB
0.1768
0.25
0.5
–2
0.252 V Peak
18 dB
0.0884
0.125
0.25
–8
0.127 V Peak
Key Path
AMPTD Y Scale
Notes
Visible only when the selected input is I/Q.
State Saved
No
Readback Text
When Range is Auto, "[Auto]"
When Range is Man and I & Q are the same, "[<range value>]"
When Range is Man and I & Q are different:
"[I: <I range value>
W-CDMA & HSPA Measurement Applications Reference
1647
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...