11 Occupied Bandwidth Measurement
Source
Key Path
Source, List Sequencer, List Sequencer Setup
Remote Command
:SOURce:LIST:STEP[1]|2|3…1000:SETup:AMPLitude <double>
:SOURce:LIST:STEP[1]|2|3…1000:SETup:AMPLitude?
Example
:SOUR:LIST:STEP2:SET:AMPL –50dBm
:SOUR:LIST:STEP2:SET:AMPL?
Notes
SCPI is supported after A.09.40
Notes
Amplitude corrections can be specified for use with the source. In the event of amplitude corrections
being applied, the valid ranges for the RF power do not change dependant on the current amplitude
correction setting. Instead, if the combination of RF power + amplitude correction is higher or lower
than the source output range, the Source Unleveled bit is set and the “Source Unleveled” indicator
will appear on status panel to indicate that the source cannot maintain the output power that has
been requested.
The multiport adapter RFIO TX ports and GPS ports cannot ensure power accuracy when power
setting is lower than –130dBm, this power setting value is defined by the sum of RF Power setting
and related amplitude correction value. But user settable value could be lower than this limit. When
application detected there exists power setting lower than –130dBm on MPA RFIO TX ports, then
popup warning message . When application detected there exists power setting lower than –
130dBm on MPA GPS ports, then popup warning message . These are only warning messages, and
check is performed when RF is ON.
Notes
The Min and Max value here defined UI settable amplitude range. This range is larger than actual
amplitude range with level accuracy defined in spec.
Dependencies
The RF power is dependent on the RF output port and frequency, such that the current frequency and
selected output port determine the valid range of power values.
Preset
–100 dBm
Min
The range of values depends on the current frequency and selected RF output port. Please refer to
and the table RF Power Range for the valid ranges.
Max
The range of values depends on the current frequency and selected RF output port. Please refer to
and the table RF Power Range for the valid ranges.
Initial S/W Revision
A.05.00
Waveform
Allows you access to the sub-menus for selecting the waveform to be played back during the current step.
Pressing this key also changes the central display area to show the Waveform File Selection view.
Key Path
Source, List Sequencer, List Sequencer Setup
Remote Command
:SOURce:LIST:STEP[1]|2|3…1000:SETup:WAVeform <string>
:SOURce:LIST:STEP[1]|2|3…1000:SETup:WAVeform?
Example
:SOUR:LIST:STEP2:SET:WAV “CW”
:SOUR:LIST:STEP2:SET:WAV?
Notes
SCPI is supported after A.09.40
Remote Command Notes
String type, takes “Off” | “CW” | “Cont” | “waveform name”
W-CDMA & HSPA Measurement Applications Reference
1541
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...