12 Code Domain Measurement
Source
CONT – continues playback of the ARB file from the previous step
CW – outputs a CW tone
OFF – disable RF output
If input parameter number exceeds the step number defined by
Number of Steps then generate error ", and only those parametes whose index number falls in
number of steps will be updated.
Dependencies
The range is 1 to 1000 which is determined by the number of steps you have configured. For details
see
"Number of Steps" on page 2803
Range
”filename” | “CW” | “Off” | “CONT”
Initial S/W Revision
A.09.40
Step Configuration of Step Duration parameter list (Remote Command Only)
This SCPI command is to configure “Step Duration” parameter array of the whole List Sequencer at one
time. The number of array is same as step number defined in
"Number of Steps" on page 2803
Number of
Steps. As a step is setup, the value entered run through several levels of validation.
Remote Command
:SOURce:LIST:SETup:DURation:TYPE <enum>, <enum>, <enum>, …
:SOURce:LIST:SETup:DURation:TYPE?
Example
:SOUR:LIST:SET:DUR:TYPE COUN,TIME,CONT
:SOUR:LIST:SET:DUR:TYPE?
Notes
The command is to setup below parameter array of whole list sequence.
Step Duration <
enum
> – specifies the duration of the step. The duration can be specified to be either
time, or play count of the ARB file associated with the step, or continuous. If Waveform is set to
“CW”, this value cannot be set to Play Count and an error will be generated. If continuous is selected,
the following Time or Count value is ignored. For further details of this setting, see
If input parameter number exceeds the step number defined by
Number of Steps then generate error ", and only those parametes whose index number falls in
number of steps will be updated.
Remote Command Notes
TIME | COUNt | CONTinuous
Dependencies
The range is 1 to 1000 which is determined by the number of steps you have configured. For details
see
"Number of Steps" on page 2803
Initial S/W Revision
A.09.40
Step Configuration of Duration Time or Play Count parameter list (Remote Command Only)
This SCPI command is to configure “Duration Time” or “Play Count” parameter array of the whole List
Sequencer at one time. The number of array is same as step number defined in
Number of Steps. As a step is setup, the value entered run through several levels of validation.
Remote Command
:SOURce:LIST:SETup:TOCount <time/int>, <time/int>, <time/int>, …
:SOURce:LIST:SETup:TOCount?
W-CDMA & HSPA Measurement Applications Reference
1929
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...