![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 2115](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616452115.webp)
13 Modulation Accuracy (Composite EVM) Measurement
Meas Setup
Remote Command
[:SENSe]:RHO:FERRor:TRANge WIDE|NORMal
[:SENSe]:RHO:FERRor:TRANge?
Example
RHO:FERR:TRAN WIDE
RHO:FERR:TRAN?
Preset
NORMal
State Saved
Saved in instrument state.
Range
Normal|Wide
Initial S/W Revision
Prior to A.02.00
PICH Code Number (BTS only)
Specifies the code number for PICH, which contains the DTX (no transmission) part. PICH has 300 bits in 1
radio frame, but the last 12 bits are not transmitted. Then, PICH needs special handling to measure code
domain power. The PICH Code Number enables you to specify which code channel should be set as PICH.
Key Path
Meas Setup, Advanced
Mode
WCDMA
Remote Command
[:SENSe]:RHO:PICH:SPRead <integer>
[:SENSe]:RHO:PICH:SPRead?
Example
RHO:PICH:SPR 16
RHO:PICH:SPR?
Notes
If PICH Code Number and MICH Code Number are the same, the channel is considered as PICH.
This parameter is meaningful only when the Symbol Boundary setting is Auto.
Dependencies
This parameter is available only when Direction is BTS.
Preset
16
State Saved
Saved in instrument state.
Min
0
Max
255
Initial S/W Revision
Prior to A.02.00
MICH Code Number (BTS only)
Specifies the code number for MICH (MBMS Indicator channel), which contains the DTX (no transmission)
part. MICH has 300 bits in 1 radio frame, but the last 6 symbols (12 bits) are not transmitted. Therefore,
MICH needs special handling to measure code domain power. The MICH Code Number specifies which
code channel should be considered as MICH.
Since MICH is an optional channel, the parameter has a BAF setting (On|Off).
W-CDMA & HSPA Measurement Applications Reference
2115
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...