12 Code Domain Measurement
Source
Mkr 1 Polarity
Allows you to set the polarity of marker 1.
Key Path
Source, Modulation Setup, ARB, Marker Utilities, Marker Polarity
Remote Command
:SOURce:RADio:ARB:MPOLarity:MARKer1 POSitive|NEGative
:SOURce:RADio:ARB:MPOLarity:MARKer1?
Example
:SOUR:RAD:ARB:MPOL:MARK1 NEG
Dependencies
When a new waveform is selected for playback the settings contained within the associated
waveform header file are applied to the ARB. The marker polarity is one of the values stored within
the header file. If the newly selected waveform file has an associated header file, the marker polarity
is updated with the value from the header file. The marker polarity will remain unchanged if the
newly selected waveform does not have an associated header file.
Preset
Pos
Range
Neg | Pos
Initial S/W Revision
A.05.00
Mkr 2 Polarity
Allows you to set the polarity of marker 2.
Key Path
Source, Modulation Setup, ARB, Marker Utilities, Marker Polarity
Remote Command
:SOURce:RADio:ARB:MPOLarity:MARKer2 POSitive|NEGative
:SOURce:RADio:ARB:MPOLarity:MARKer2?
Example
:SOUR:RAD:ARB:MPOL:MARK2 NEG
Dependencies
When a new waveform is selected for playback the settings contained within the associated
waveform header file are applied to the ARB. The marker polarity is one of the values stored within
the header file. If the newly selected waveform file has an associated header file, the marker polarity
is updated with the value from the header file. The marker polarity will remain unchanged if the
newly selected waveform does not have an associated header file.
Preset
Pos
Range
Neg | Pos
Initial S/W Revision
A.05.00
Mkr 3 Polarity
Allows you to set the polarity of marker 3.
Key Path
Source, Modulation Setup, ARB, Marker Utilities, Marker Polarity
Remote Command
:SOURce:RADio:ARB:MPOLarity:MARKer3 POSitive|NEGative
:SOURce:RADio:ARB:MPOLarity:MARKer3?
Example
:SOUR:RAD:ARB:MPOL:MARK3 NEG
Dependencies
When a new waveform is selected for playback the settings contained within the associated
W-CDMA & HSPA Measurement Applications Reference
1879
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...