![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 1922](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616451922.webp)
12 Code Domain Measurement
Source
Key Path
Source, Modulation Setup, ARB
Dependencies
This key is only available if there is currently a waveform selected for playback. If no waveform is
selected, the key is grayed out.
Initial S/W Revision
A.05.00
Continuous
Sets the current step to be played continuously until the next step starts. The waveform will always play
completely before transitioning to the next step.
Key Path
Source, List Sequencer, List Sequencer Setup, Step Duration
Example
:SOUR:LIST:STEP2:SET:DUR:TYPE CONT
Notes
SCPI is supported after A.09.40
Initial S/W Revision
A.05.00
Output Trigger
Allows you to specify the trigger output for the current step. The trigger output signal is sent at the start of
the step.
When select “On”, trigger event will occur on both Internal and External2 paths. Select “Off” will turn off
trigger output.
Key Path
Source, List Sequencer, List Sequencer Setup
Remote Command
:SOURce:LIST:STEP[1]|2|3…1000:SETup:OUTPut:TRIGger ON | OFF | 1 | 0
:SOURce:LIST:STEP[1]|2|3…1000:SETup:OUTPut:TRIGger
Example
:SOUR:LIST:STEP2:SET:OUTP:TRIG ON
:SOUR:LIST:STEP2:SET:OUTP:TRIG?
Notes
SCPI is supported after A.09.40
Preset
Off
Range
On|Off
Initial S/W Revision
A.05.00
Step Configuration (Remote Command Only)
This SCPI command is used to configure the List Sequencer and is detailed in the table below. The
command is defined such that you send one command per step, with the step number being specified as a
subopcode of the SCPI command. Each command includes all the parameter settings for the step. As a
step is setup, the values entered are run through several levels of validation.
Remote Command
:SOURce:LIST:STEP[1]|2|...|4..1000:SETup IMMediate | INTernal | KEY |
1922
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...