15 Power Control Measurement
Meas
Key Path
Meas Setup
Mode
WCDMA
Remote Command
:CONFigure:PCONtrol
Example
CONF:PCON
Notes
You must be in the W-CDMA mode to use this command. Use INSTrument:SELect to set the mode.
Couplings
Selecting meas preset restores all measurement parameters to their default values.
Initial S/W Revision
Prior to A.02.00
Filter Alpha
Sets the alpha value of the root raised cosine (RRC) filter.
Key Path
Meas Setup, Advanced
Mode
WCDMA
Remote Command
[:SENSe]:PCONtrol:FILTer[:RRC]:ALPHa <real>
[:SENSe]:PCONtrol:FILTer[:RRC]:ALPHa?
Example
PCON:FILT:ALPH 0.22
PCON:FILT:ALPH?
Notes
You must be in the W-CDMA mode to use this command. Use INSTrument:SELect to set the mode.
Preset
0.220
State Saved
Saved in instrument state.
Min
0.01
Max
0.50
Initial S/W Revision
Prior to A.02.00
Chip Rate
Changes the chip rate for the measurement.
Key Path
Meas Setup, Advanced
Mode
WCDMA
Remote Command
[:SENSe]:PCONtrol:CRATe <freq>
[:SENSe]:PCONtrol:CRATe?
Example
PCON:CRAT 3.84e6
PCON:CRAT?
Notes
You must be in the W-CDMA mode to use this command. Use INSTrument:SELect to set the mode.
Preset
3.84 MHz
State Saved
Saved in instrument state.
W-CDMA & HSPA Measurement Applications Reference
2675
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...