![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 2012](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616452012.webp)
13 Modulation Accuracy (Composite EVM) Measurement
AMPTD Y Scale
•
"Ref Position: Slot CDE/EVM View – Peak CDE Window" on page 2013
•
"Ref Position: Slot CDE/EVM View – Freq Error Window" on page 2014
Key Path
AMPTD Y Scale
Initial S/W Revision
Prior to A.02.00
Ref Position: I/Q Error View - EVM Window
Sets the reference position of the vertical axis in the EVM window.
Key Path
AMPTD Y Scale
Mode
WCDMA
Remote Command
:DISPlay:RHO:VIEW2:WINDow[1]:TRACe:Y[:SCALe]:RPOSition TOP | CENTer |
BOTTom
:DISPlay:RHO:VIEW2:WINDow[1]:TRACe:Y[:SCALe]:RPOSition?
Example
DISP:RHO:VIEW2:WIND:TRAC:Y:RPOS TOP
DISP:RHO:VIEW2:WIND:TRAC:Y:RPOS?
Preset
BOTTom
State Saved
Saved in instrument state.
Initial S/W Revision
Prior to A.02.00
Ref Position: I/Q Error View – Mag Error Window
Sets the reference position of the vertical axis in the magnitude error window.
Key Path
AMPTD Y Scale
Mode
WCDMA
Remote Command
:DISPlay:RHO:VIEW2:WINDow2:TRACe:Y[:SCALe]:RPOSition TOP | CENTer |
BOTTom
:DISPlay:RHO:VIEW2:WINDow2:TRACe:Y[:SCALe]:RPOSition?
Example
DISP:RHO:VIEW2:WIND2:TRAC:Y:RPOS TOP
DISP:RHO:VIEW2:WIND2:TRAC:Y:RPOS?
Preset
CENTer
State Saved
Saved in instrument state.
Initial S/W Revision
Prior to A.02.00
Ref Position: I/Q Error View – Phase Error Window
Sets the reference position of the vertical axis in the phase error window.
2012
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...