15 Power Control Measurement
Source
Where:
reference frequency equals the original RF frequency entered under Source>Frequency>Frequency and
set as the reference frequency
entered frequency equals a new value entered under Source>Frequency>Frequency
In addition, the displayed frequency value will be the same as the value entered under
Source>Frequency>Frequency.
If Freq Reference is set to ON with a reference value set, entering a value under
Source>Frequency>Frequency and pressing Set Frequency Reference will add that value to the existing
Freq Reference value.
If you wish to change the reference frequency value to the new value entered under
Source>Frequency>Frequency, first you must set Freq Reference to OFF and then press Set Frequency
Reference.
Key Path
Source, Frequency
Remote Command
:SOURce:FREQuency:REFerence:SET
Example
:SOUR:FREQ:REF:SET
Dependencies
This setting is unavailable, and is grayed out when the List Sequencer is turned ON.
Initial S/W Revision
A.05.00
Freq Reference
This key allows you to toggle the state of the frequency reference. When the frequency reference state is
ON, an annunciator is displayed on the main source view to indicate this state to the user.
When you use a frequency reference, the signal generator outputs a frequency that is set relative to the
reference frequency by the value entered under Source>Frequency>Frequency as follows:
Output frequency = reference fre entered frequency
Where:
reference frequency equals the original RF frequency entered under Source>Frequency>Frequency and
set as the reference frequency
entered frequency equals a new value entered under Source>Frequency>Frequency
For more information on Reference Frequency refer to
"Set Reference Frequency" on page 2754
Key Path
Source, Frequency
Remote Command
:SOURce:FREQuency:REFerence <freq>
:SOURce:FREQuency:REFerence?
:SOURce:FREQuency:REFerence:STATe OFF|ON|0|1
:SOURce:FREQuency:REFerence:STATe?
Example
:SOUR:FREQ:REF 0.00 Hz
W-CDMA & HSPA Measurement Applications Reference
2755
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...