14 QPSK EVM Measurement
Source
Key Path
Source, List Sequencer, List Sequencer Setup
Remote Command
:SOURce:LIST:STEP[1]|2|3…1000:SETup:INPut:TRIGger IMMediate | INTernal
| EXTernal2 | KEY | BUS | EXTernal4
:SOURce:LIST:STEP[1]|2|3…1000:SETup:INPut:TRIGger?
Example
:SOUR:LIST:STEP2:SET:INP:TRIG BUS
:SOUR:LIST:STEP2:SET:INP:TRIG?
Notes
SCPI is supported after A.09.40
Preset
Free Run
Range
Free Run | Internal | Manual (Trigger Key) | Bus | External 2| EXTernal4
Initial S/W Revision
A.05.00
Free Run
Sets the trigger input for the current step to Free Run.
Key Path
Source, List Sequencer, List Sequencer Setup, Step Trigger
Example
:SOUR:LIST:STEP2:SET:INP:TRIG IMM
Notes
SCPI is supported after A.09.40
Initial S/W Revision
A.05.00
Internal
Sets the trigger input for the current step to Internal.
Key Path
Source, List Sequencer, List Sequencer Setup, Step Trigger
Example
:SOUR:LIST:STEP2:SET:INP:TRIG INT
Notes
SCPI is supported after A.09.40
Initial S/W Revision
A.05.00
Manual (Trigger Key)
Sets the trigger input for the current step to Manual (Trigger Key). Any step in the sequence set to Manual
will cause the sequence execution to stop until the manual trigger key is pressed. Sending the Bus Trigger
SCPI command will have no effect. At any point in the sequence where the list sequencer is paused waiting
for a software trigger, a pop up dialog is displayed until the trigger event occurs.
Key Path
Source, List Sequencer, List Sequencer Setup, Step Trigger
Example
:SOUR:LIST:STEP2:SET:INP:TRIG KEY
Notes
SCPI is supported after A.09.40
Initial S/W Revision
A.05.00
W-CDMA & HSPA Measurement Applications Reference
2549
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...