15 Power Control Measurement
Index: n
Results Returned
The number of slots is the first parameter from :MEASure:PCONTrol?.
7
Chip by chip phase error trace.
Returns a series of floating point numbers (in degrees) that represents chip by chip phase error.
The number of values returned is equal to the number of chips in the capture interval.
8
Chip phase error best-fit line.
Returns a series of floating point numbers (in degrees) that represents best-fit phase line of chips
to minimize the EVM of the slot.
The number of values returned is equal to the number of chips in the capture interval.
9
Slot Phase Discontinuity.
Returns a series of floating point numbers (in degrees) that represents phase difference between
the end of the previous slot and the beginning of the slot.
The number of values returned is equal to the number of slots in the capture interval.
10
Slot phase error from the reference phase at the beginning of the slot.
Returns a series of floating point numbers (in degrees) that represents absolute phase error at
the beginning of each slot.
The number of values returned is equal to the number of slots in the capture interval.
11
RMS EVM of slots based on the best-fit line.
Returns a series of floating point numbers (in degrees) that represents RMS EVM of each slot
excluding 25us at the beginning and tail of the slot.
The number of values returned is equal to the number of slots in the capture interval.
12
RMS Magnitude error of slots.
Returns a series of floating point numbers (in degrees) that represents RMS Magnitude error of
each slot excluding 25us at the beginning and end of the slot.
The number of values returned is equal to the number of slots in the capture interval.
13
RMS Phase error of slot.
Returns a series of floating point numbers (in degrees) that represents frequency error of each
slot, which is an element of the RMS EVM.
The number of values returned is equal to the number of slots in the capture interval.
14
IQ Offset of slots.
Returns a series of floating point numbers (in dB) that represents IQ Origin Offset of each slot,
which is an element of the RMS EVM.
The number of values returned is equal to the number of slots in the capture interval.
15
Frequency error of the best-fit line for slots.
Returns a series of floating point numbers (in Hz) that represents frequency error of each slot,
which is equivalent to the amount of the slope of the best-fit line and frequency error of the
reference frequency that measurement algorithm determines for synchronization, and an
element of the RMS EVM
The number of values returned is equal to the number of slots in the capture interval.
W-CDMA & HSPA Measurement Applications Reference
2621
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...