![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 1006](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616451006.webp)
10 Spectrum Emission Mask Measurement
AMPTD Y Scale
[:SENSe]:POWer[:RF]:RANGe:MIXer:OFFSet?
Example
POW:RANG:MIX:OFFS –5 dB
Preset
0 dB
State Saved
Saved in instrument state
Min
–35 dB
Max
30 dB
Initial S/W Revision
A.13.00
Scale/Div
Sets the units-per-division of the vertical scale in the logarithmic display. When Auto Scaling is On, the
scale per division value is automatically determined by the measurement result. When you set a value
manually, Auto Scaling automatically changes to Off.
Key Path
AMPTD Y Scale
Mode
SA, WCDMA, C2K, WIMAX OFDMA, TD-SCDMA, 1xEVDO, DTMB (CTTB), DVB-T/H, ISDB-T, CMMB,
LTE, LTETDD, Digital Cable TV, WLAN, MSR, LTEAFDD, LTEATDD
Remote Command
:DISPlay:SEMask:VIEW[1]:WINDow[1]:TRACe:Y[:SCALe]:PDIVision <rel_ampl>
:DISPlay:SEMask:VIEW[1]:WINDow[1]:TRACe:Y[:SCALe]:PDIVision?
Example
DISP:SEM:VIEW:WIND:TRAC:Y:PDIV 15dB
DISP:SEM:VIEW:WIND:TRAC:Y:PDIV?
Notes
You must be in the mode that includes SEM measurement to use this command. Use
:INSTrument:SELect to set the mode.
Couplings
When the Auto Scaling is On, this value is automatically determined by the measurement result.
When you set a value manually, Auto Scaling automatically changes to Off.
Preset
10 dB
State Saved
Saved in instrument state
Min
0.10 dB
Max
20.00 dB
Initial S/W Revision
Prior to A.02.00
Modified at S/W Revision
A.02.00, A.03.00
Ref Position
Positions the reference level at the top, center or bottom of the Y scale display. Changing the reference
position does not affect the reference level value.
Key Path
AMPTD Y Scale
Mode
SA, WCDMA, C2K, WIMAX OFDMA, TD-SCDMA, 1xEVDO, DTMB (CTTB), DVB-T/H, ISDB-T, CMMB,
LTE, LTETDD, Digital Cable TV, WLAN, MSR, LTEAFDD, LTEATDD
1006
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...