13 Modulation Accuracy (Composite EVM) Measurement
Source
Segment Advance
Sets the active trigger type to Segment Advance. If Segment Advance is already selected as the active
trigger type, pressing this key allows access to the segment advance trigger type setup menu.
Segment Advance triggering allows you to control the playback of waveform segments within a waveform
sequence. When a trigger is received the ARB advances to the next waveform segment within the
waveform sequence. This type of triggering ignores the repetition count for the waveform segment within
the waveform sequence. For example, if a waveform segment has a repetition count of 10 and you select
single segment advance triggering mode, the waveform segment will only play once.
Segment Advance triggering can also be used for waveform segments only. In this situation the same
waveform segment is played again when a trigger is received.
Key Path
Source, Modulation Setup, ARB, Trigger Type
Remote Command
:SOURce:RADio:ARB:TRIGger:TYPE:SADVance[:TYPE] SINGle | CONTinuous
:SOURce:RADio:ARB:TRIGger:TYPE:SADVance[:TYPE]?
Example
:SOUR:RAD:ARB:TRIG:TYPE:SADV SING
Preset
CONTinuous
Range
Single | Continuous
Initial S/W Revision
A.05.00
Single
Selects Single as the trigger response for Segment Advance trigger type. With single selected, once a
trigger is received a segment is played once. If a trigger is received during playback of a segment, the
segment plays to completion and the next segment is played once.
Key Path
Source, Modulation Setup, ARB, Trigger Type, Segment Advance
Example
:SOUR:RAD:ARB:TRIG:TYPE:SADV SING
Initial S/W Revision
A.05.00
Continuous
Selects Continuous as the trigger response for Segment Advance trigger type. With continuous selected,
once a trigger is received a segment is played continuously. When subsequent triggers are received, the
currently playing segment plays to completion and then the next segment is played continuously.
Key Path
Source, Modulation Setup, ARB, Trigger Type, Segment Advance
Example
:SOUR:RAD:ARB:TRIG:TYPE:SADV CONT
Initial S/W Revision
A.05.00
W-CDMA & HSPA Measurement Applications Reference
2213
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...