12 Code Domain Measurement
Meas Setup
Symbol Boundary (BTS only)
Opens a menu that enables you to specify the symbol boundary detection mode on downlink.
Available selections are as follows:
•
Auto Detect [SCPI Enum: AUTO] - Select this to set the symbol boundary detection to the automatic
mode. Various code channels are measured and the most appropriate code channel is selected as the
reference channel.
•
Test Model 1 - Accesses a menu with further selections of Test Model 1 with 4, 8, 16, 32 or 64 DPCH
channels and with S-CCPCH.
−
Test Model 1 w/4DPCH w/ S-CCPCH [SCPI Enum: TM1D4] - Select this to set the Code Domain
Power Measurement to the Test Model 1 with 4 DPCH channels and 1 S-CCPCH channel.
−
Test Model 1 w/8DPCH w/ S-CCPCH [SCPI Enum: TM1D8] - Select this to set the Code Domain
Power Measurement to Test Model 1 with 8 DPCH channels and 1 S-CCPCH channel.
−
Test Model 1 w/16 DPCH w/ S-CCPCH [SCPI Enum: TM1D16] - Select this to set the Code Domain
Power Measurement to the Test Model 1 with 16 DPCH channels and 1 S-CCPCH channel.
−
Test Model 1 w/32 DPCH w/ S-CCPCH [SCPI Enum: TM1D32] - Select this to set the Code Domain
Power Measurement to Test Model 1 with 32 DPCH channels and 1 S-CCPCH channel.
−
Test Model 1 w/64 DPCH w/ S-CCPCH [SCPI Enum: TM1D64] - Select this to set the Code Domain
Power Measurement to Test Model 1 with 64 DPCH channels and 1 S-CCPCH channel.
•
Test Model 2 - Accesses a menu to allow selections of Test Model 2 with S-CCPCH.
−
Test Model 2 w/S-CCPCH [SCPI Enum: TM2SC] - Select this to set the Code Domain Power
measurement to Test Model 2 with 1 S-CCPCH channel.
•
Test Model 3 - Accesses a menu to allow further selections from Test Model 3 with 16 or 32 DPCH
channels, and with S-CCPCH.
−
Test Model 3 w/4 DPCH w/ S-CCPCH [SCPI Enum: TM3D4SC] - Select this to set the Code Domain
Power Measurement to Test Model 3 with 4 DPCH channels and 1 S-CCPCH channel.
−
Test Model 3 w/8 DPCH w/ S-CCPCH [SCPI Enum: TM3D8SC] - Select this to set the Code Domain
Power Measurement to Test Model 3 with 8 DPCH channels and 1 S-CCPCH channel.
−
Test Model 3 w/16 DPCH w/ S-CCPCH [SCPI Enum: TM3D16SC] - Select this to set the Code
Domain Power measurement to Test Model 3 with 16 DPCH channels and 1 S-CCPCH channel.
−
Test Model 3 w/32 DPCH w/ S-CCPCH [SCPI Enum: TM3D32SC] - Select this to set the Code
Domain Power measurement to Test Model 3 with 32 DPCH channels and 1 S-CCPCH channel.
•
Test Model 4 - Accesses a menu to allow further selections of Test Model 4.
−
Test Model 4 w/P-CPICH [SCPI Enum: TM4CP] - Select this to set the Code Domain Power
measurement to Test Model 4 with 1 CPICH channel.
−
Test Model 4 [SCPI Enum: TM4] - Select this to set the Code Domain Power measurement to Test
Model 4 (no CPICH channel).
1726
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...