6 System Functions
System
Example
:SYST:DATE “2006,05,26”
Notes
<year> is the four digit representation of year. (for example, 2006)
<month> is the two digit representation of year. (for example. 01 to 12)
<day> is the two digit representation of day. (for example, 01 to 28, 29, 30, or 31) depending on the
month and year
Unless the current account has Power User or Administrator privileges, an error will be generated by
this command and no action will be taken.
Initial S/W Revision
Prior to A.02.00
Time (Remote Command Only)
Sets or queries the time in the instrument.
Mode
All
Remote Command
:SYSTem:TIME “<hour>,<minute>,<second>”
:SYSTem:TIME?
Example
:SYST:TIME “13,05,26”
Notes
<hour> is the two digit representation of the hour in 24 hour format
<minute> is the two digit representation of minute
<second> is the two digit representation of second
Unless the current account has Power User or Administrator privileges, an error will be generated by
this command and no action will be taken.
Initial S/W Revision
Prior to A.02.00
Module Name (Remote Command Only)
Query only. This will return the name of the instance as displayed on the xSA main window.
Mode
All
Remote Command
:SYSTem:MODule:NAME?
Example
:SYST:MOD:NAME?
Notes
If the first instance displays on the xSA main window, the return string is “TRX1”. If the second
instance displays on the main window, the return string is “TRX2”. If the third instance displays on the
main window, the return string is ‘TRX3”. If the fourth instance displays on the main window, the
return string is “TRX4”.
Preset
Not affected by Preset, reset to “Left” with Restore System Defaults Misc.
State Saved
No
Initial S/W Revision
A.13.80
W-CDMA & HSPA Measurement Applications Reference
273
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...