![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 280](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_1961645280.webp)
6 System Functions
System
State Saved
No
Initial S/W Revision
Prior to A.02.00
Configure Applications
The Configure Applications utility can be used to:
•
select applications for preload
•
determine how many applications can fit in memory at one time
•
specify the order of the Modes in the Mode menu.
This utility consists of a window with instructions, a set of “Select Application” checkboxes, a “fuel bar”
style memory gauge, and keys that help you set up your configuration.
In products that run multiple instances of the X-Series Application, the same Configure Applications Utility
is shared between all the instances.
For more information, see the following topics:
"Preloading Applications" on page 280
"Access to Configure Applications utility" on page 281
"Virtual memory usage" on page 281
Key Path
System, Power On
Example
:SYST:SHOW CAPP Displays the Config Applications screen
Initial S/W Revision
A.02.00
Preloading Applications
During runtime, if a Mode that is not preloaded is selected using the Mode menu or sending SCPI
commands, there will be a pause while the Application is loaded. During this pause a message that says
“Loading application, please wait …” is displayed. Once loaded, the application stays loaded, so the next
time you select it during a session, there is no delay.
Preloading enables you to “preload” at startup, to eliminate the runtime delay. Preloading an application
will cause it to be loaded into the analyzer’s memory when the analyzer program starts up. If you do this,
the delay will increase the time it takes to start up the analyzer program, but this may be preferable to
having to wait the first time you select an application. Note that, once an application is loaded into
memory, it cannot be unloaded without exiting and restarting the analyzer program.
Note that there are more applications available for the X-Series than can fit into Windows Virtual Memory.
By allowing you to choose which licensed applications to load at startup, the Configure Applications utility
allows you to make optimal use of your memory.
280
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...