![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 1655](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616451655.webp)
12 Code Domain Measurement
AMPTD Y Scale
Key Path
AMPTD Y Scale
Initial S/W Revision
Prior to A.02.00
Power Graph & Metrics View CDP Window Y Scale/Div
Sets the vertical display sensitivity measurement result in the Power Graph & Metrics view of the CDP
window.
Key Path
AMPTD Y Scale
Mode
WCDMA
Remote Command
:DISPlay:CDPower:VIEW[1]:WINDow[1]:TRACe:Y[:SCALe]:PDIVision <real>
:DISPlay:CDPower:VIEW[1]:WINDow[1]:TRACe:Y[:SCALe]:PDIVision?
Example
DISP:CDP:VIEW:WIND:TRAC:Y:PDIV 5.0
DISP:CDP:VIEW:WIND:TRAC:Y:PDIV?
Notes
Target window to control depends on the SubOpCode.
Preset
10.00
State Saved
Saved in instrument state.
Min
0.10
Max
20.00
Initial S/W Revision
Prior to A.02.00
CDP Graph & CDE Graph View CDP Window Y Scale/Div
Sets the vertical display sensitivity measurement result for Code Domain Power and Code Domain Error
graph views in the CDP window.
Key Path
AMPTD Y Scale
Mode
WCDMA
Remote Command
:DISPlay:CDPower:VIEW2:WINDow[1]:TRACe:Y[:SCALe]:PDIVision <real>
:DISPlay:CDPower:VIEW2:WINDow[1]:TRACe:Y[:SCALe]:PDIVision?
Example
DISP:CDP:VIEW2:WIND:TRAC:Y:PDIV 5.0
DISP:CDP:VIEW2:WIND:TRAC:Y:PDIV?
Notes
Target window to control depends on the SubOpCode.
Preset
10.00
State Saved
Saved in instrument state.
Min
0.10
Max
20.00
Initial S/W Revision
Prior to A.02.00
W-CDMA & HSPA Measurement Applications Reference
1655
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...