12 Code Domain Measurement
View/Display
Key Path
View/Display, Power Graph & Metrics
Mode
WCDMA
Remote Command
:CALCulate:CDPower:SBOundary:COMPosite OFF|ON|0|1
:CALCulate:CDPower:SBOundary:COMPosite?
Example
CALC:CDP:SBO:COMP ON
CALC:CDP:SBO:COMP?
Notes
Only valid for CDPower Bar Graph window and CDE Graph window.
Dependencies
This command is effective only when the [:SENSe]:CDPOwer:CAPTure:TIME(Capture Interval) is set to
0.067, 1.0, 2.0 and 3.0.
Couplings
Setting this parameter off activates the Symbol Rate key.
Preset
ON
State Saved
Saved in instrument state.
Range
On|Off
Initial S/W Revision
Prior to A.02.00
Symbol Rate
Sets the display symbol rate to read the total power level of the combined code channels defined by the
:CALCulate:CDPower:SRATe command.
The functions of Display Symbol Rate for Power Bar Graph and CDE Graph are coupled to each other.
Key Path
View/Display, Power Graph & Metrics
Mode
WCDMA
Remote Command
:CALCulate:CDPower:SBOundary:SRATe <integer>
:CALCulate:CDPower:SBOundary:SRATe?
Example
CALC:CDP:SBO:SRAT 30000
CALC:CDP:SBO:SRAT?
Notes
Only valid for CDP Bar Graph window and CDE Graph window.
192000 choice for MS is available only when HSPA is enabled.
Dependencies
This key is unavailable when Composite is On.
Couplings
The functions of Display Symbol Rate for Power Bar Graph and CDE Graph are coupled to each other.
Preset
15000
State Saved
Saved in instrument state.
Range
7500|15000|30000|60000|120000|240000|480000|960000 for BTS
15000|30000|60000|120000|240000|480000|960000|1920000 for MS
Default Unit
sps
Initial S/W Revision
Prior to A.02.00
Modified at S/W Revision
A.03.00
1974
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...