![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 2328](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616452328.webp)
13 Modulation Accuracy (Composite EVM) Measurement
View/Display
State Saved
Saved in instrument state.
Min
1
Max
2560
Initial S/W Revision
Prior to A.02.00
+45° Rotation
Toggles the display rotation function between On and Off. When set to On, the I/Q polar vector or I/Q polar
constellation graph is rotated by +45 degrees to provide a rectangular display.
Key Path
View/Display, I/Q Measured Polar Graph
Mode
WCDMA
Remote Command
:DISPlay:RHO:VIEW[1]:WINDow2:TRACe:ROTQpi[:STATe] 0|1|OFF|ON
:DISPlay:RHO:VIEW[1]:WINDow2:TRACe:ROTQpi[:STATe]?
Example
DISP:RHO:VIEW:WIND2:TRAC:ROTQ ON
DISP:RHO:VIEW:WIND2:TRAC:ROTQ?
Preset
OFF
State Saved
Saved in instrument state.
Range
On|Off
Initial S/W Revision
Prior to A.02.00
Full Vector
Toggles the full vector display function between On and Off. When set to On, the full vector traces in gray
are displayed in the background of the polar vector solid traces in yellow.
Key Path
View/Display, I/Q Measured Polar Graph
Mode
WCDMA
Remote Command
:DISPlay:RHO:VIEW[1]:WINDow2:TRACe:FVECtor[:STATe] 0 | 1 | OFF | ON
:DISPlay:RHO:VIEW[1]:WINDow2:TRACe:FVECtor[:STATe]?
Example
DISP:RHO:VIEW:WIND2:TRAC:FVEC ON
DISP:RHO:VIEW:WIND2:TRAC:FVEC?
Dependencies
Grayed out when the selected view is I/Q Measured Polar Graph and the selected I/Q Polar
Vec/Constln is Constellation.
Preset
OFF
State Saved
Saved in instrument state.
Range
On|Off
Initial S/W Revision
Prior to A.02.00
2328
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...